7. Repairing minor faults

The generating set...
Does not start
or
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply
electrical current

8. Technical specifications

8.1. Operating conditions

The stated outputs of the generating sets are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
Generating set performance is reduced by approximately 4% for every additional 10° C and/or approximately 1% for every additional
100m in altitude. Generating sets can only operate while stationary.
8.2. Capacity of the generating set (overload)
Before connecting and operating the generating set, calculate the electrical power required by the devices to be used (in watts)*. When
running several devices simultaneously, never exceed the rated load of the generating set (in amps and/or watts) when it is operating
continuously.
*This load is usually indicated in the technical specifications or on the device manufacturer's plate. Some devices require a higher load
when starting. This minimum required power must not exceed the generating set's maximum power.
Check that:
The devices to be used have not been
connected prior to starting.
YES
The ON/OFF switch is positioned at
YES
The oil level is correct, the oil cut-out
warning light is off.
YES
The fuel level is correct.
YES
The fuel tap is
in the "ON" position.
YES
The fuel tank vent
is open.
YES
Maintenance has been correctly
performed on the generating set
components.
YES
Have the generating set checked by one
of our agents*.
The circuit breaker for the 12V socket
is triggered.
YES
The capacity of the generating set is not
exceeded; the overload warning light is
off.
YES
The connected devices and their power
cords are not faulty.
YES
Have the generating set checked by one
of our agents*.
Solutions to be applied:
Disconnect the devices then try to restart
the generating set.
NO
.
Position the ON/OFF switch at
NO
Top up with oil.
NO
Fill up with fuel.
NO
Turn the fuel tap
NO
to the "ON" position.
Turn the fuel tank vent one turn anti-
NO
Perform maintenance on the generating set
in accordance with the recommendations
NO
Press the circuit breaker for the 12V socket
NO
Reduce the load.
NO
Try with another device and another power
cord.
NO
.
clockwise.
to trigger it.