A PP (step mode) command activates the opening manoeuvre. With the gate fully open, automatic reclosure is exclu
ded. Another PP (step mode) command activates the closure manoeuvre.
A PED (partial opening) command activates the partial opening manoeuvre. Automatic reclosure is excluded. Another
PED (partial opening) command activates the closure manoeuvre.
Adjusting opening delay (alignment) of MOTOR 2
During opening, MOTOR 2 starts with an adjustable delay after MOTOR 1.
From 0 to 10 s.
Adjusting closing delay (alignment) of MOTOR 1
During closing, MOTOR 1 starts with an adjustable delay after MOTOR 2.
From 0 to 30 s.
Setting reverse time after activation of sensing edge or obstacle detection
(crush prevention)
This sets the reverse manoeuvre time after activation of the sensing edge or the obstacle detection system.
From 0 to 60 s.
Electric lock mode selection
Normally UNPOWERED electric lock (powered only for 3 s when opening starts).
N.B.
"ventouse" type electric block (normally powered when the gate is completely closed). Not powered when gate is moving.
"ventouse" type electric block (normally powered when the gate is completely opened or completely closed). Not powe
red when gate is moving.
Electric lock of normally NOT powered type, with adjustable timing
=0.5 seconds;
=1 second;
Enable electric lock
Disabled.
Enabled. When LEAF 1 approaches the gate closed stop, the controller delivers supplementary power to MOTOR 1 to
latch the electric lock.
Enabled. When LEAF 1 approaches the gate closed stop, the controller delivers maximum power to MOTOR 1 to latch
the electric lock. The obstacle detection system is disabled.

Setting motor torque

Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a result, adjusts
obstacle detection sensitivity.
Use values below
SOLO ONLY for particularly lightweight installations not exposed to severe weather conditions
(strong winds or very cold temperatures). In installations with gate leaves of different lengths, they torque value may
be set separately, setting a value for parameter
= 0%.
= +8%;
= +16%;
= +25%;
Setting obstacle impact force sensitivity MOTOR 1
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact force exerted
on obstacles is too high, reduce the value of parameter
N.B: repeat the acquisition procedure after any change made to this parameter.
= minimum obstacle impact force ...
N.B.
Medium motor torque. Recommended setting for adjusting force settings correctly.
= minimum obstacle impact force ...
Maximum motor torque. May only be used if the gate is equipped with a sensing edge.
Setting obstacle impact force sensitivity MOTOR 2
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact force exerted
on obstacles is too high, reduce the value of parameter
N.B: repeat the acquisition procedure after any change made to this parameter.
= minimum obstacle impact force ...
N.B.
.
=1.5 seconds.
between
and
(reduced motor torque = increased sensitivity).
= +35% (increased motor torque = reduced sensitivity).
.
= maximum obstacle impact force
= maximum obstacle impact force.
(or
= maximum obstacle impact force
.