6
Description of connections
6.1
Typical installation
8
9
3
10
It is the installer's responsibility to verify the adequacy of the cables in relation to the
devices used in the installation and their technical characteristics.
1
Power supply
Motor 1
2
Motor 2
3
4
LED Flashing light R92/LED24 - FIFTHY/24
5
Power supply 24Vdc
6
Antenna
Key selector R85/60
7
Key pad H85/TTD - H85/TDS
(connecting to H85/DEC - H85/DEC2)
H85/DEC - H85/DEC2
8
(connecting to control unit)
Gate open indicator
9
Power supply 24V DC 3W max
Courtesy light (Potential free contact)
10
Power supply 230 Vac (100 W max)
SUGGESTIONS: with existing installations, we recommend checking the cross section of the cables and that
the cables themselves are in good condition.
56
5
1
6
4
2
F4ES/F4S
F4ES/F4S
Recommended cable
double insulated cable
2
Cable 3x2,5 mm² (max 10
Cable 3x2,5 mm² (max 10
Cable 5x0,5 mm
(max 20 m)
2
Cable 3x0,5 mm
(max 20 m)
2
Cable 2x1 mm
(max 10 m)
2
Cable 50 Ohm RG58 (max 10 m)
Cable 3x0,5 mm
(max 20 m)
2
Cable 2x0,5 mm
(max 30 m)
2
Cable 4x0,5 mm
2
(max 20 m)
The number of conductors increases when using more than
one output contact on H85/DEC - H85/DEC2
Cable 2x0,5 mm
(max 10 m)
2
Cable 2x1 mm
(max 20 m)
2
7
3
2
4
3x4 mm² (max 30 m)
3x4 mm² (max 30 m)