Descargar Imprimir esta página

Position Recovery With The Absolute Encoder (Smarty Range Only); Initial Testing; Maintenance - Roger Technology EDGE1/BOX Instrucciones Y Advertencias Para El Instalador

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 158
• stops the motors for 0.4 s.
• the wings resume the manoeuvre at low speed through to the striker plate.
• On the subsequent Step by Step command (PP), the wings carry out the manoeuvre at low speed again.
4. Leave the wings to carry out a complete manoeuvre to restore normal operation mode.
19
Position recovery WITH the absolute encoder (SMARTY
range only)
encoder to reacquire the position of the gate leaf immediately.
If the control unit detects that the gate leaves are not positioned correctly, it corrects the error automatically.
open cycle and then closes the leaves after 1 s (even if automatic closure is not enabled) to restore the correct
alignment.
Warning: Do not use any controls until the gate has performed a complete manoeuvre for both leaves.
20

Initial testing

The installer is required to measure impact forces and select on the control unit the appropriate speed and torque
12445.
Make sure that the provisions in Chapter 1 "GENERIC WARNINGS are observed.
• Turn on the power supply.
• Check that the automation system motors rotate in the correct direction. If the leaves do not move correctly, swap
• Check that all connected controls are working correctly.
• Check travel and deceleration.
• Check that the impact force is correct, in compliance with EN 12453 and EN12445.
• Check that the safety devices are activated correctly.
gate leaves must not move.
• If the battery kit is installed, disconnect from mains and check that the batteries are working.
• Disconnect from mains power and disconnect the batteries (if used), then reconnect. Check the correct completion
of the position recovery phase when opening and when closing.
• For SMARTY Series automation systems with absolute encoder installed, disconnect and reconnect power. Perform
a manoeuvre with the controls and check that the speed and deceleration values are correct. The position recovery
manoeuvre is not performed.
• If
(SMARTY REVERSIBLE only), check that the gate leafs are locked when the motors are stopped.
21

Maintenance

Perform scheduled maintenance every 6 months.
Check cleanliness and function.
If the unit contains dirt, moisture, insects or other foreign matter, disconnect from mains power and clean the board
and the housing.
Repeat the initial installation test procedure after cleaning.
If any corrosion is found on the printed circuit board, evaluate if it is necessary to replace the board itself.
Check that the battery is in good working order.
Check the SMARTY 5R5 and 7R motors are braking properly.
84