O . M . I . S . A . S r l
Via Verga 9/11
20845 Sovico (MB), Italy
If during the auto-test an error is detected, a "System Error"
message shows on the display. When this happens, the report
generator has to be disconnected from the power suppy and
the welding machine and has to be returned to the manu-
Caution
facturer for repair.
During the auto-test several screens resembling Display 2 appear. They
inform the welder of the currently selected pressure and temperature
sensor, the current outside temperature, power supply voltage, time,
and date as well as of the kind of machine and welding standard
selected at that point. By pressing the MENU key, you can access the
Configuration Menu to change all parameters to be applied to the im-
minent welding which are not currently selected as they should be.
Then Display 3 appears with the parameters that will be used for the
next welding (the joint number will show only if this function has been
enabled in the Configuration Menu). From this screen it is possible to
access the Configuration Menu in which the default behavior of the
data logger can be configured. To access it, press the MENU key and
then, on the following enter code screen, enter the access code using
the cursor keys or hold the transponder card with the menu access
code in front of the RFID reader.
To enter information using the cursor keys, proceed as fol-
lows: The ï and ð cursor keys position the cursor at the
desired digit/character on the display screen. The ñ and ò
cursor keys are used to select the value (letter, number) that
Info
should appear at this place. In general, the START/SET must
then be pressed to confirm that input.
Pressing the ñ and ò cursor keys in the menu that appears (Display 4),
you can select a menu option, then access the selected sub-menu by
pressing the MENU key again.
In the Machine Data sub-menu, the type of machine (its designation
and its cylinder section) to which the hydraulic, control, and data log-
ging/report generation unit is connected, has to be defined (see the
arrow symbol in Display 5). To change the selected machine, select
the desired machine type by pressing the ñ or ò cursor keys and con-
firm by pressing the START/SET key. For added safety, the section of
the selected machine's cylinder is once more displayed and has to be
confirmed again by START/SET.
An access code is required to open the Machine Data sub-menu. This
code will be disclosed only to authorized personnel with the operat-
ing company.
If the wrong machine is selected in this menu, all pressure
computations that the unit makes, will be wrong! Changing
to another machine requires consultation with the manufac-
Important
turer or an authorized service shop, as a sensor calibration is
then also recommended. This step requires proper authoriza-
tion.
As an addition to the preinstalled machines, user-defined types can
be set as needed at the unused menu entries (a designation for the
machine and its cylinder section have to be entered). Enter the required
data using the cursor keys and confirm by START/SET.
From the Configuration Menu's Sensor Parameters option, the tem-
perature sensor (PT100, PT1000) and the pressure sensor (160 bar,
250 bar, 600 bar) can be selected/calibrated (see Display 6).
Version June 2020
SPG 2.0 User's Manual
****Machine Data****
HST-355
Cylinder
:
06.60
Pres.Sens.:
160bar
Display 2
Next welding
15:44:52
29.05.12
235V
135C/220C
Rep. No. 00072/00002
Display 3
CODE : 415311
Settings
-M-
>Reporting
-M-
Sensor Parameter-M-
Machine Data
-M-
Display 4
**Machine Chassis***
>HST 250
05.10
HST 315
05.89
HST 355
06.60
Display 5
SENSOR PARAMETERS
>Calib. Heat.El. -M-
Calib. Press.S. -M-
Display 6
9
EN