O . M . I . S . A . S r l
Via Verga 9/11
20845 Sovico (MB), Italy
before the first welding operation after switching the unit on or
only after the first welding operation of a new day/date.
"Language – M – " means that by pressing the MENU key, the user
can access a sub-menu for selecting the display and report lan-
guage (see Sect. 4.2.2).
"Date/Time – M – " means that by pressing the MENU key, the user
can access a sub-menu for setting the clock (see Sect. 4.2.3).
"Buzzer Volume – M – " means that by pressing the MENU key, the
user can access a sub-menu for setting the volume of the status
buzzer (see Sect. 4.2.4).
"Temperature Unit – M – " means that by pressing the MENU key, the
user can access a sub-menu for selecting centigrade or Fahrenheit
as the unit for the temperature.
"Pressure Unit – M – " means that by pressing the MENU key, the user
can access a sub-menu for selecting bars or pounds per square
inch (psi) as the unit for the pressure.
"Length Unit – M – " means that by pressing the MENU key, the user
can access a sub-menu for selecting metric or U. S./Imperial units
for the length.
"Inventory Number – M – " means that by pressing the MENU key,
the user can access a sub-menu for entering the number under
which the unit is inventorized with the operating company.
"Number of Tags – M – " means that by pressing the MENU key, the
user can access a sub-menu for entering the number of tags that
are printed automatically after welding with the optional label
tag printer if such a printer is connected.
"Standard – M – " means that by pressing the MENU key, the user can
access a sub-menu for selecting the standard (guideline, norma-
tive scheme) applicable to the welding operation.
4.2.2 Selecting the Display Language
When the "Select Language" sub-menu was selected, the screen
changes and the display reproduced in Display 9 appears.
Use the arrow keys ñ and ò to select one of the options, "Deutsch,"
"English," "Français," and so on and confirmby pressing the START/
SET key.
4.2.3 Setting the Clock
When the "Set Clock" sub-menu was selected, the screen changes and
the display reproduced in Display 10 appears.
The time of day and the date can be set using the keypad. The portions
"Hour," "Minute," "Day," "Month," and "Year" are set separately.
Press the START/SET key to confirm your settings.
4.2.4 Setting the Buzzer Volume
When the "Set Volume" sub-menu was selected, the screen changes
and the display reproduced in Display 11 appears. The buzzer can also
be heard. Turn the buzzer volume up or down to the desired value
using the ï, ð arrow keys (from 0 to 100) and confirm your setting
by pressing the START/SET key.
4.2.5 Understanding the "Recording" Sub-menu
"Welder Code on" means that the welder identification code has to
be entered as set with "Welder Code Options," "off," that this
is impossible.
"Commission Number on" means that the commission number (job
number) will have to be entered or confirmed before every new
welding, "off" that the user is not prompted to enter it.
Version June 2020
SPG 2.0 User's Manual
***** LANGUAGE *****
>Deutsch
English
Francais
Display 9
Date/Time
21.06.13
14:28
Display 10
Buzzer Volume
< ------20-------- >
Display 11
CONFIGURATION **
**
>Welder Code
On
Commission No.
On
Joint No.
Off
Display 12
EN
11