Setting The Default Configuration Of Machine Operation; Understanding The "Settings" Sub-Menu - omisa SPG 2.0 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Use the ñ or ò cursor keys to select the desired item and press the
MENU key to confirm your selection. Under Calibrate Pressure Sensor,
you can calibrate for connected the machine, i.e. determine the zero
pressure point for the sensor. To do so, move the carriage to the far-
thest point and then press the START/SET key. The display screen then
shows the reference pressure, e. g. 80.0 bar if the 160 bar pressure
sensor is currently selected (see Display 7). The displayed reference
pressure, which is not the same for all available pressure sensors, has to
be set on the machine using its pressure gauge, and the display value,
to be adjusted accordingly using the ñ or ò cursor keys. By pressing
the START/SET key, the data are saved to the system.
The heating element can be calibrated under the Calibrate Heating
Element option. Use the ñ or ò cursor keys and the START/SET key in
the same manner.
When matching the displayed value to the reference using
the ñ and ò keys, holding the respective key down will make
the values change faster.
Info
4.2 Setting the Default Configuration of Machine Operation
In the sub-menus of the Configuration Menu, at "Settings," the pa-
rameters related to the welding unit itself and its operation can be
set. At "Recording," the traceability data that have to or need not be
recorded and written into the reports can be enabled or disabled. The
desired sub-menu is selected using the ñ and ò arrow keys. Then to
access that sub-menu, press the MENU key.
In both parts of the configuration menu, use the ñ and ò arrow keys
to select the desired set-up option. Use the ð arrow key to toggle
between "on" and "off" for that set-up option.
If a "M" is shown next to a set-up option, this indicates that a sub-
menu is accessible here by pressing the MENU key.
On both menu levels (Configuration Menu and its respective
sub-menus), press the START/SET key to save the settings to
memory or press the STOP/RESET key to return to the previ-
Important
ous menu level without saving possible changes.

4.2.1 Understanding the "Settings" Sub-menu

"Check Code Expiry on" means that the welder identification code has
to be current and not expired (default period of validity 2 years
from code issuance), or the welding operation cannot be started,
"off," that the validity of the code is not checked at all.
"Memory Control on" means that when the system memory is full of
reports, the unit will be blocked until the reports are printed or
downloaded, "off," that it works but that the oldest report will
be overwritten.
"Manual Input on" means that the manual input of welding param-
eters or computed parameters is possible, "off," that the manual
input is not allowed.
"Check Ambient Temperature on" means that the outside tempera-
ture is measured before welding, "off," that it not; if the tem-
perature is below 0°C (32°F), welding should be performed only
after taking appropriate steps (heating, tent, for instance).
"Welder Code Options – M – " means that by pressing the MENU
key, the user can access a sub-menu that allows determining
when the welder code, if it is enabled at "Recording," has to be
entered:always, i. e. before evey single welding operation, only
10
EN
SPG 2.0 User's Manual
O . M . I . S . A . S r l
Via Verga 9/11
20845 Sovico (MB), Italy
Calib. Press. Values
[SET]
Act. Pres. : 80.0bar
Nom. Pres. : 00.0bar
Display 7
SETTINGS
***
***
Check Code Exp. Off
Memory Control
On
>Manual Input
On
Display 8
Version June 2020