Menu 3 Basic settings
Menu
Entry
Selection
item
30
Door setting of upper end position
Reversal of the direction (press for 5 s)
31
Door setting of lower end position
33
Fine correction of upper end position
50
Factory settings
50 - 0
0...80 mm lower
50 - 99 0...80 mm higher
34
Fine correction of lower end position
50
Factory settings
50 - 0
0...80 mm lower
50 - 99 0...80 mm higher
35
Selection of closing edge safety device
Measurement display (press 5 seconds)
0
Optical closing edge safety device OSE (de-
fault setting)
1
Electrical safety edge 8K2
2
Pressure wave switch with testing
3
Electrical safety edge 8K2 with slack rope
switch
4
Wireless closing edge, RadioBand
36
Selection of photoelectric sensor
0
Without photoelectric sensor (default setting)
1
2-wire photoelectric sensor LS2
2
4-wire photoelectric sensor LS5 photoelectric
reflection sensor
3
Photoelectric sensor LS2, mounted in frame
4
Photoelectric sensor LS5 photoelectric reflec-
tion sensor mounted in frame
5
2-wire photoelectric sensor LS2 with stop
function for opening
6
4-wire photoelectric sensor LS5 with stop
function for opening
37
Correction of pre-limit switch closing edge safety
25
Correction of pre-limit switch closing edge
safety (default setting)
25 - 0
0...50 mm lower
25 - 99 0...100 mm higher
- -
Exit menu
30 - EN
Menu 4 Further door settings
Menu
Entry
item
40
Selection of operating mode
0
1
2
41
Response to closing edge safety device
0
1
42
Overtravel correction
0
1
43
Floor adjustment
0
1
2
3
4
45
Status relay X5
0
1
2
3
4
5
6
7
8
46
Status relay X6
0
1
2
3-12
13-22
47
Spring fracture detection
0
1-99
48
Opening force limitation
0
1-98
99
49
Motor duty cycle
0
1
2
3
4
5
6
- -
TAD MS 400V / 230V
Selection
Dead man OPEN / dead man CLOSE
Pulse OPEN / dead man CLOSE
Pulse OPEN / pulse CLOSE (default setting)
Full reversing (default setting)
Partial reversing
Off
On (default setting)
Off (default setting)
Advanced end stop by closing edge
Floor adjustment activated for 200 cycles
Floor adjustment activated for 1000 cycles
Permanent floor adjustment
Door close signal (default setting)
Door open signal / dock light
2-minute garage light
5-minute garage light
On/off with hand-held transmitter
ELTACO wipe pulse
Warning signal for automatic return
Red/green traffic light with door sealing
Control of electronic door lock EDL100 (op-
tional)
Door close signal
Door open signal (default setting)
Red light without advance warning time
Advance warning time before closing 1 s -
10 s
Advance warning time before opening and
closing 1 s - 10 s
Spring balance indication (press for 5 s)
Off (default setting)
Entry of spring force
Off (default setting)
Entry of switch-off force
Carry out weight measurement run with test
weight
Without limitation (default setting)
Geared motor 5.24 (25 min / 35 %)
Geared motor 5.24 WS (25 min / 30 %)
Geared motor 9.15, 9.20, 9.24 (25 min / 60 %)
Geared motor 9.24 WS (25 min / 20 %)
Geared motor 6.65 DU (10 min / 35 %)
Geared motor 14.15 (25 min / 60 %)
Exit menu