WARNING
DO NOT use on asphalt. Lift must be on concrete with a minimum strength of 3000PSI and a minimum
thickness of 4.5". Maximum allowed floor slope is 1/8" per foot side to side of vehicle and 1/4" per foot front to rear of
vehicle. DO NOT use on a suspended floor structure without specific approval from structural engineer.
Ensure vehicle tires are properly inflated before lifting.
DO NOT exceed tire load rating when raising vehicle.
DO NOT raise/lower only one side of a vehicle.
Lift only on same axle. DO NOT stagger between axles.
WARNING
Permit only trained personnel to operate lift. After reviewing these instructions, become familiar with
the lift controls by running the lift through a few cycles before loading a vehicle on lift. Observe and heed SAFETY and
WARNING labels on the lift.
WARNING
This motor has internal arcing or sparking parts. To minimize the Risk of Explosion, DO NOT expose to
flammable vapors.
OPERATING CONDITIONS: Lift is not intended for outdoor use or storage and has an operating ambient temperature range
of 41º-104ºF (5º-40ºC). This product is intended for indoor use only in a dry location.
DO NOT use lift in a manner other than intended. Included (but not limited to) examples of unapproved uses of the lift are:
lifting vehicle by only one side, lifting different axles with a column pair (lifting on the diagonal), and lifting non-approved
items.
5