A - ENGLISH
CHARGING GEL/AGM (VRLA) BATTERIES
Charge the batteries each time the machine is used or when the Battery Indicator (O) is reading less than fully charged.
WARNING!
Charge batteries in a well-ventilated area. If battery acid makes contact with your skin, flush the affected area with water for 5
minutes and seek medical attention.
Do not smoke while servicing the batteries.
When Servicing Batteries...
*
Remove all jewelry
*
Do not smoke
*
Wear safety glasses, rubber gloves and a rubber apron
*
Work in a well-ventilated area
*
Do not allow tools to touch more than one battery terminal at a time
*
ALWAYS disconnect the negative (ground) cable first when replacing batteries to prevent sparks.
*
ALWAYS connect the negative cable last when installing batteries.
CAUTION!
Your valve regulated lead acid (VRLA) battery will deliver superior performance and life ONLY IF IT IS RECHARGED PROPERLY!
Under or overcharging will shorten battery life and limit performance. Be sure to FOLLOW PROPER CHARGING INSTRUCTIONS!
DO NOT ATTEMPT TO OPEN THIS BATTERY! If a VRLA battery is opened, it loses its pressure and the plates become oxygen
contaminated. THE WARRANTY WILL BE VOIDED IF THE BATTERY IS OPENED.
The machine utilizes a shelf charger. To begin charging do the following:
1
Turn the machine off at the Key Switch (27).
Tip the seat forward to open the Battery Compartment (10) set the Prop Rod.
2
3
Disconnect the batteries from the machine and push the connector from the charger into the Battery Pack Connector (39).
SERVICE NOTE: Make sure you plug the battery charger into the connector that attaches to the batteries.
4
Refer to the charger's OEM product manual for more detailed operating instructions.
NOTE: Rely on the status lights on the charger (and its OEM manual) to verify when the batteries are completely charged. This may take several hours
depending upon the condition of the batteries before charging.
IMPORTANT: Make sure you have an appropriate charger for use on Gel cell batteries. Use only "voltage-regulated" or "voltage-limited" chargers.
Standard constant current or taper current chargers MUST NOT be used.
A - 46
INSTRUCTIONS FOR USE
Nilfisk Liberty SC60 - 56091234