Do not remove the power cord ground prong.
It is suggested that power cord should be H07RN-F 3X1.5mm2 (approved according to EN 50525-2-21),
welding cable should be H01N2-D 1X10mm2 and external fuse should be 40A. The recommended Torch is
25% 100A (approved according to EN 60974-7). Only approved power cord, welding cable, Torch can be
used together with the machine.
8. ASSEMBLY AND INITIAL USE MMA PROCESS
Note: It is necessary to use an electrode holder that complies with the NMX-J-038/11-ANCE standard. Use
a helmet in accordance with regulations and that has protective glasses in accordance with regulations,
the level of protection (shade) must be at least 9-10. There should be a slag hammer and wire brush.
Before assembling make sure that the power switch is turned off and that the power socket of the
equipment is disconnected.
Connect the work cable to the ground socket with the negative (-) symbol (MMA)
Connect the torch to the ground socket with the negative symbol (-) (TIG)
Insert the coupling into the socket, and then turn it clockwise until it clicks. Pull on the coupling device to
ensure it is properly coupled. These coupling devices must be clean and free of oil.
Connect the electrode cable to the socket with the positive symbol (+). (MMA)
Connect work cable to socket with positive (+) symbol. (TIG)
Insert the coupling into the socket marked positive (+), and then turn it clockwise. Pull on the coupling
device to verify that it is properly coupled. These coupling devices must be clean and free of oil.
Power switch
This switch allows you to turn the equipment on and off with an audible click.
Transport Strap
Use it to transport the equipment easily and safely. The installation of the transport strap is carried out in
the slits in the upper part of the plastic housings of the equipment.
5. Operation
Environment conditions
a) Operating ambient temperature: −10 ℃ 〜 + 40 ℃
Transport and storage temperature: −20 ℃ 〜 + 55 ℃
b) Relative humidity: Up to 50% at 40 ℃ and up to 90% at 20 ℃
c) Operating environment with normal levels of dust, acid, corrosive gases
that are not different from those produced by the welding process and that
allow adequate ventilation.
d) Equipment must be positioned less than 10 ° from the horizontal.
Warning
If the machine is placed more than 10 ° from the horizontal, it can rotate on its axis causing damage.