DIP Switch Functions
Fixed-fuction DIP Switches
A1
Test Mode (normally Off).
A2
In "ON" position, add one high-speed pump (or blower) with Heater.
A3
In "ON" position, add two high-speed pumps (or 1 HS Pump and Blower) with Heater.
A4
In "ON" position, add four high-speed pumps (or 3 HS Pumps and Blower) with Heater.
A5
In "ON" position, enables Special Amperage Rule B. See Special Features section under Configuration Options for functionality with your system.
In "OFF" position, enables Special Amperage Rule A.
A6
Persistent memory reset (Used when the spa is powering up to restore factory settings as determined by software configuration).
A2, A3, and A4 work in combination to determine the number of high-speed devices and blowers that can run before the heat is disabled. i.e. A2 and A3 in the ON position
and A4 in the OFF position will allow the heater to operate with up to 3 high-speed pumps (or two HS Pumps and Blower) running at the same time. Heat is disabled when the
fourth high-speed pump or blower is turned on.
Note: A2/A3/A4 all off = No heat with any high-speed pump or blower.
Assignable DIP Switches
A7
In "ON" position, enables a 5-minute cooldown for some gas heaters (Cooling Time B).
In "OFF" position, enables a 1-minute cooldown for electric heaters (Cooling Time A).
Undesignated switches are not assigned a function.
Jumper Definitions
J109
Not present on BP6013 board.
J91
Not present on BP6013 board.
J30
Do Not Use
J31
Jumper on 1 pin with 2.0kW or smaller heater
Jumper on 2 pins with a 3.0kW or higher heater
J29
Heater Disable Switch Connection. If J29 is shorted by any means, the heater will not run until J29 is no longer shorted.
If J29 is shorted during power-up "J29" will appear on the panel.
The message can be dismissed with a button press, and is the only control panel notification of J29 being shorted.
No message is displayed if J29 is shorted after power-up, but the heater will not run until J29 is no longer shorted.
J29 expects a switch closure (not a voltage) as the command signal.
In some areas, a local power company may offer discounts based on voluntary "power shedding" devices that may be installed in conjunction with the spa.
J25, J26, J27
Not present on BP6013 board.
J24
Jumper on center two pins (230V) when heater is running at 240V.
Two Jumpers installed; one on left 2 pins and one on right 2 pins (115V) when heater is running at 120V.
Warning!
Setting DIP switches or jumpers incorrectly may cause abnormal system behavior and/or damage to system components.
Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
Contact Balboa if you require additional configuration pages added to this tech sheet.
Replacement Parts
PCBA:
Main PCBA:
Expander PCBA:
36
HEATER(s):
56613-02 3.0kW Models
Plug + Click Heater Kit:
56732-01 2.0kW Models
N/A
Temp Sensor:
CABLES:
FUSES:
Part Number
58300 3.0kW 800 Inc
58301 3.0kW 825 INC
30136
58302 3.0kW Titanium
20600
58289 2.0kW 800 Inc
26397
30344
30122
N/A
ON
1
10
S1
J31
J29
230V
J24
115V
115V
Amperage
Location
30A
F6, F8
3A
F4
1/8A
F3
10A
F2, F7