Descargar Imprimir esta página

Sanycces SPA407 Manual De Instalacion Y Uso página 80

Ocultar thumbs Ver también para SPA407:

Publicidad

Idiomas disponibles

Idiomas disponibles

Basic Functions Setup 1-9
Power Requirements:
Single Service [3 wires (line, neutral, ground)]
230VAC, 50/60Hz*, 1þ, 32A, (Circuit Breaker rating = 40A max.)
Dual Service [5 wires (line 1, neutral 1, line 2, neutral 2, ground)]
230VAC, 50/60Hz, 2þ, 16A, (Circuit Breaker rating = 20A max each phase line.)
3-Service [5 wires (line 1, line 2, line 3, neutral, ground)]
400VAC, 50/60Hz*, 3þ, 16A, (Circuit Breaker rating = 20A max each phase line.)
System Ouputs:
Pump 1
230VAC
2-Speed
6.5A - 12A max
1 Speed in Setups in Setups 2, 4, 6
Pump size is dependent on service available (16A vs. 32A), other equipment installed, and if A5 is set to ON for Special Amperage Rule B.
in Setups 1, 3, 5, this is the heater pump.
Must deliver 20 GPM through heater
Pump 2
230VAC
1-Speed
6.5A - 12A max
Pump size is dependent on service available (16A vs. 32A), other equipment installed, and if A5 is set to ON for Special Amperage Rule B.
Used in setups 1, 2 & 7
Blower
230VAC
1-Speed 4A max
Used in Setup 3, 4 & 8
Circ Pump 230VAC
1-Speed
2A max
This is the heater pump in Setups 2, 4, 6 - 9.
Must deliver 20 GPM through heater
Ozone
230VAC
.5A max
Slaved to Circ Pump in Circ Setups 2, 4, 6 - 9.
Independent in Non-Circ Setups 1, 3 & 5.
Spa Light 10VAC
On/Off
1A max
A/V (Stereo) 230VAC
Hot
4A max
Heater
3.0kW @ 240VAC max
2.0kW @ 240VAC max
BP6013G1 SYSTEM
PUMP 1
A/V
CIRC PUMP
15-minute timer (30-minute timer for P1 Low in non-circ setups only)
15-minute timer
15-minute timer
Programmable Filtration Cycles + Polling
240-minute timer.
Always on
PUMP 2 OR BLOWER
OZONE
DIP SWITCH
LIGHT
IMPORTANT - Service must include a neutral wire, with a line to neutral voltage of
230VAC.
*BP systems automatically detect 50Hz vs 60Hz.
Migrating from BP601G1:
If you are migrating from the BP601G1 model to this BP6013G1 model:
• The remiaining 3 Setups are new Setups that allows a 2-Speed Pump1 to be used
along with a Circ Pump (which is not possible on the BP601G1).
WIFI TRANSEIVER
33

Publicidad

loading

Productos relacionados para Sanycces SPA407

Este manual también es adecuado para:

Spa409