iInstallation: electrical requirements
ELECTRICAL WIRING INSTRUCTIONS
Have a licensed electrician run the required 230-volt power line to the spa installation site. This power line must be permanently connected (hard-wi-
red) to the mains supply. Do not use extension cords or plug-in type connections. At the site where the spa is to be located leave 5 metres of cable
and secure with the appropriate cable gland. All electrical wiring to a hot tub / spa must be installed by a qualifi ed, licensed
electrician, and meet local building/electrical codes. A certifi cate from the electrician verifying it has been tested must be obtained.
PLEASE NOTE: Failure to supply the recommended power will void the Manufacturer's Warranty.
For all spas the power supplied must be red protected dedicated supply - see previous page for supply rating. To connect your spa follow these
instructions:
Ensure that the power supplyis shut off prior to connection. To be carried out by qualifi ed personnel only:
1) Remove the access panel from the front of the spa cabinet.
2) To access the power terminal strip, remove the cover from the control box.
3) Feed the mains power supply into the box through one of the removable cable entry points. Fit a cable gland (not supplied) to the box and con-
nect securely to the panel.
4) Connect wires to terminal block. All wires must be connected and tightened securely, or damage may result.
5) Replace the control box cover. Electrical connection is now complete.
Neutrol - Terminal 2
Fase - Terminal 3
Ground - Outder power box terminal
230V
6) A Green coloured terminal or a terminal marked Ground is located in the supply terminal box/compartment or on the side of the box. This termi-
nal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the
circuit conductors supplying the equipment, to reduce the risk of electric shock.
7) "BONDING LUGS" are provided on the external surface of the supply terminal box/compartment. All fi eld installed metal components such as
rails, ladders, drains or other similar hardware within 3 metres of the spa or hot tub must be bonded to the bonding lugs with a continuous copper
wire equivalent in size to the supply conductors
8
IN SETUPS 3, 4 & 8
J25=HTR1
J21
J26=HTR2
J9
J33
K9
J27=HTR3
K4
J30=TEST
J46
J31=CE
J38
HTR
SEL
K2
J39
J10 J43
F6 30A
J60
J41
F8 30A
1
F3 0.125A SLO-BLOW
TB1
K1
1
K3
2
2
J49
J48
BLU
BRN
2
3
3
K5
3
GRN
4
J53 J58
J111
J11
4
230V
1þ
1x32A &
1x16A
SENSOR A
3.0 kW HEATER
HEIZELEMENT
RADIATEUR
J14
J32
J13
K8
J19
J34
J35
MAIN
MAIN
230V
J24
J5
115V 115V
J107
T1
AUX
J101
J23
SERIAL
J22
J30
J31
J15
J29
VAC
LIGHT
K7
HTR
DISBL
F4 3A SLO-BLOW
10
J17
J16
GND
AUX
ON
S1
J28
FRZ
SENSOR B