Descargar Imprimir esta página

DAL DEGAN SOFIA Manual De Uso Y Mantenimiento página 67

Publicidad

PULVERIZADORES SUSPENDIDOS - PORTABLE ATOMIZERS
TROUBLESHOOTING
PROBLEMS
The pump does not load.
The pump does not reach the
RATING PLATE pressure.
3
DX+SX
2
Suction of air.
Control unit lever not at zero.
Valves and/or valves seat worn or
dirty.
Suction filter ring nut loose.
Suction filter circlip not positioned
in the seat and/or opened.
Suction filter cartridge clogged.
Suction tube clogged (A) between
the tank and three-way cock.
Three-way cock (B) in the wash po-
sition.
Cock (C) open.
Yellow plug (D) not correctly fitted.
Control unit valve and/or valve seat
worn.
Valve and/or valve seats worn or dirty.
Insufficient number of revolutions.
Worn nozzles.
Suction and or delivery filters (E)
partially clogged.
5
DX
4
SX
GB
CAUSES
Escape by-pass
By-pass outlet
CURES
Check suction apparatus.
Slacken the adjustment valve.
Turn the adjustment unit lever to posi-
5
= no pressure. Change or clean.
tion
Check tightness.
Position the circlip in the seat or replace
it.
Wash the cartridge filter.
Remove the suction tube and clean it.
Refit in the work position.
Close the cock.
Remove the yellow plug and refit it cor-
rectly.
Replace.
Replace or clean.
Reinstate number of PTO rpm.
Replace nozzles.
Clean the filter cartridges, close the cock
(C) of the self-cleaning delivery filter.
1
Presión
Pressure
68

Publicidad

loading

Este manual también es adecuado para:

SaturnVolkanSakanOdiseo