Anchors will not stay tight. 1.Latch shafts rusted. (Usually
Locking latches do not
engage.
Locking latches do not
disengage.
Lift stops short of full rise
or chatters.
Lift will not raise off of
latches
occurs on outside installations or in
high humidity areas such as vehicle
wash bays.)
2.Latch spring broken.
3.Latch cable needs adjustment.
1.Latch cable is broken.
2.Cable is off sheaves/upper guides.
3.Latch cable is loose.
1.Low oil level.
2.Air in hydraulic lines/cylinder.
Lift stops short of full rise or chatters. 1.Fill tank to proper level with ISOVG32
Motor, pump, or cylinder failure
0496-M004-0
1.Relocate lift using a new bit to
drill holes. Reference installation
instructions for minimum spacing
requirements.
2.Break out old concrete and repour
new pads for lift per lift installation
instructions.
1. Remove covers, oil latch mechanism.
Actuate latch release handle several
times to allow oil to coat shaft.
2.Replace broken spring.
3.Adjust clamp at cable end per lift
installation instructions.
1.Replace cable.
2.Check position of cable on sheaves/
upper guides; adjust cable tension.
3.Adjust cable tension.
Hydraulic Oil or Dexron III ATF.
2.Bleed lift per installation instructions.*
*Lifts with bleeders only.
1.Contact lift manufacturer's Customer Service.