AQUA-BASE
ARUBA Comfort
Technical manual
Always use dubble hose clambs in order to have an extra failsafe, pressure resistant connection
between the hose and the fitting.
To assemble a pipe on its fitting, proceed as shown on the figure:
1 - Place the hose clamps, without tightening, then place the pipe
on the fitting,
2 - Slide the hose clamps to the fitting level and tighten them.
Ref.:
Caracteristics:
Connection type:
A1
Ø25*33
A2
Translucent
reinforced 5 bar
SLCE Ref.: 301189
A3
A8
Hose clamps
Ø19*27
A4
20bar
BLACK PVC
A5
FOOD approval
A6
SLCE Ref.: 717303
A7
Ø8*13
B1
20bar
Hose clamps or
BLACK PVC
Quick fitting
B2
FOOD approval
SLCE Ref.: 717276
B3
In case of installation of the auto-flush option:
Ø10*12
Hose clamps or
C1
RILSAN TUBE
Quick fitting
SLCE Ref.: 719218
*The flushing subset is to be installed between the strainer (F02) and the feeding pump (P04) except when the sandfilter
option is also installed. In this case the flushing subset is to be installed between the sandfilter subset and the prefiltration
subset. (the A4 hose)
Supplemental hydraulic connections to be made on the MODULAR version:
D1
SLCE Ref.: 710098
HP line connexions
D2
E1
Ø8*10
E2
RILSAN TUBE
Quick fitting
SLCE Ref.: 719107
E3
Ø4*6
F1
Quick fitting
SLCE Ref.: 719080
After the first time starting up the watermaker, thoroughly check each hydraulic connection for eventual
leaks.
•
Connects:
Seawater inlet (V0) (hull fitting and valve not supplied) to the intake valve (V01)
- Seawater strainer (F02) to the feeding pump (P04)
or
- Seawater strainer (F02) to the flushing valve (V17) (if this option is installed) *
Flushing valve (V17) (if this option is installed) * to the feeding pump (P04)
Auxiliary tank (not supplied) to the intake valve (V01)
- Feeding pump (P04) to the prefiltration (F30-F32)
or
- Feeding pump (P04) to sandfilter inlet (if this option is installed) *
Prefiltration (F30-F32) to the watermaker inlet (PWI)
Watermaker outlet (SWO) to the 3-way cleaning valve (V50)
3-way cleaning valve (V50) to the auxiliary tank
- Watermaker fresh water outlet (FWO) to the neutralite filter (if installed)
- Watermaker fresh water outlet (FWO) to 3-way sampling valve (if installed)
- Watermaker fresh water outlet (FWO) to on-board fresh water tank
3-way sampling valve to on-board fresh water tank
3-way sampling valve to sampling recipient
On board pressurized fresh water supply to the auto flush subset (FWI)
(The water from the on-board water network cannot contain more than 0.4 mg/L of
chlorine)
HP pump subset to the Membrane pack subset
Membrane pack subset to the regulating valve (V49) on the control-panel.
Membrane pack subset to the flow indicator (Fi61) on the control-panel.
Flow indicator (Fi61) on the control-panel to the production valve subset
Production valve subset to reject valve.
Low-pressure pressure-line from HP pump subset to the LP pressure indicator
(Pi33) on the control-panel.
REV.J
P12/108