5.
Switch the 3-way sample valve to the sample outlet and place the sample tube (B3) also in the
auxiliary tank. (See §4.9)
6.
Place the inlet valve (V01) to cleaning position to complete the closed loop and completely open the
regulating valve (V49).
Cleaning position inlet valve V01:
7.
If your installation is equipped with a sandfilter, make sure its by-passed (see §3.4).
8.
Start the unit up, by pressing the FLUSHING button for 5 seconds. A 15 minutes closed loop cleaning
cycle will start. When the 15 minutes have passed, the unit will stop automatically.
During the membrane cleaning cycle, pressure should be reduced to minimum (open position of (V49)
the regulating valve).
9.
Empty the solution out of the auxiliary tank and clean it with fresh declorinated mains water.
10. Put the cleaning valve (V50) in reject position.
11. Flush the membrane(s) as described before.
12. Fill the auxiliary tank with 10 litres of fresh water produced by the unit, or dechlorinated mains water.
13. Prepare the Acid solution "MC3"(from the cleaning kit) by mixing it in the auxiliary tank.
14. Put the cleaning valve (V50) in cleaning position to go back to closed loop.
15. Start the unit up, by pressing the FLUSHING button for 5 seconds. The 15 minutes closed loop
cleaning cycle will start.
16. Empty the solution out of the auxiliary tank and clean it with fresh dechlorinated water.
17. Direct the 3-way sample valve to the freshwater storage tank, the cleaning valve (V50) in reject
position, the inlet valve (V01) back to its normal position and readjust the pressure regulating valve
(V49) as discribed in § 3.1
18. Flush the membrane(s) as described before.
NB: Membrane cleaning can be done in the factory or by your agent on a specialised bench, in a more thorough
way. Contact your agent or the factory directly.
4.8.3
When should the membrane(s) be replaced?
A membrane has a lifetime of about 5 years. Then, as the plastic materials harden, the pores retighten
and production will decrease. Then, you must replace the membrane.
Or if the membrane has accidentally has taken in fuel or oil, it also must be replaced.
To replace a reverse osmosis membrane, please contact us directly or through one of our dealers, to
obtain the membrane replacement specification sheet, by communicating the serial number of the
watermaker.
4.9
Trouble-shooter
In case of problems with the unit, it is possible to download the trouble-shooter of the unit on the web
site of the manufacturer
Closed loop position reject valve V50:
"first start-up"
.
SLCE watermakers:
https://slce-watermakers.com/behind password access.
Open the regulating valve (V49)
REV.J
P24/108