1.3.3
Electrical components
To have a complete overview of the electrical system, consult the corresponding electric diagram in the
chapter§5 "the annexes".
Interface
Emergency stop
Production button (START)
Stop button (STOP)
Membrane maintenance button (FLUSHING)
Sand filter BACKWASH button
2 LEDs indicating production salinity
General fault LED (ALARM)
Electric power box
24VCC 60W Power supply
Transformer
(three phase models)
Motor breaker
(three phase models)
Motor breaker
(single phase models)
Circuit breaker
(single phase models)
Circuit breaker
Fuse 1A (5 X 20)
Fuse 2.5A (5 X 20)
Electric control box
Programmable logic controller
Conductivity meter PCB + interface
1.3.4
Interface
All the main controls are found on the front of the machine on the convenient control panel.The remote
control option is described in chapter § 2.7.
The main control, indicator and regulation interfaces:
9.
8.
10.
NB: Modular models have the complete interface mentionned above, situated on a single control panel (see A3-02).
The EMERGENCY STOP button is located on the
power-box. Once pushed, the power is cut from
the pumps and all its functions stop immediately.
To undo this action, slightly turn the EMERGENCY
STOP button and it'll pop back in its original
position. The STOP button and the ALARM
warning light blink when the emergency stop
button is triggered.
(on the electric power box)
(option)
7.
1.2.3.4.5.6.
1. The "production" button
2. The "stop" button
3. The "membraneflushing" button
4. The "sandfilter backwash" button
5. A RED "alarm/default" warning light
6. A red and green salinity indicator light
7. A running-hour meter
8. A high- and a low-pressure pressure gauge
9. The pressure regulating valve (V49)
10. The freshwater flow meter (in liter/hour)