Technical manual
3.4.3
Other options
Installation of other options do not alter the operation of the unit.
3.5
Installed safeties
AQUA-BASE ARUBA Comfort
watermaker and the on-board installation in case of overpressure, lack of water, too high salinity of the
produced water, etc....
The low- and a high-pressure analog pressure sensor PSn34 (set to a minimum of 0.5 bar) and
PSn43 (set to a maximum of 68 bar) before they give a signal to shut off the machine in order to
protect its components.
The salinity probe (CE62) coupled with the automated production valve (V64) assures only water
produced with the correct salinity (< 750ppm) enters the freshwater tank. When the salinity
exceeds 750ppm (1500 µS.cm
water is directed to the discharge. *
The pressure gauges and flowmeter provide read-out of the running parameters.
In case the machine detects an electric or hydraulic anomaly, the watermaker will stop and indicate a
fault with the START, STOP and ALARM lights.
Emergency stop STOP & ALARM blinking slow
Low-pressure fault START, STOP & ALARM blinking slow
High-pressure fault START blinks slow and STOP & ALARM blinking fast
Electric fault STOP & ALARM staying on & START blinks slow**
Reset the machine by pressing the stop button for 5 seconds and search the origin of the fault.
If you need assistance in resolving or identifying the source of the problem, ordering replacement parts,
or need operating advice, do not hesitate to contact your nearest
* In case of a salinity fault, there is a possibility to bypass the alarm; access the production valve (V64) behind the
front cover (see §4.5) and force the valve in production mode.
In normal functioning the valve
button is in this position.
The machine will produce water and direct it to the freshwater tank regardless of the salinity. It is
recommended to use a portable conductivity meter to check the quality of the produced water.
model has base of safety features which are all designed to protect the
) for more than 5 minutes, the machine indicates alarm and the
-1
(**START only if a fault has occurred with the machine running)
To force the valve in production,
press the button and turn it a
quarter of a turn to the right to
maintain its forced position.
AQUA-BASE
agent.
To release the button, turn it a
quarter turn to the left. The button
returns to its original state.
REV.J
P18/108