4b. Electrical suppressor device
It is mandatory to install the coil suppressor, please see the instructions below:
4c. Trigger input by circulation pump
220 Vac 50 Hz
Circulation pump
Connect the Trigger cable as the example on
the site with the traditional circulation pump,
to check the fl ow is present in the pipe line.
Specifications
Pump state
Probe calibration
Power supply
Consumption (W)
Device precision
Accuracy
Range
Flow rate pump (l/h)
Max. back-pressure
Relay contact (number 3)
Fuse
Weight
Dimensions (W–H–D)
Trigger input cable
5. SPECIFICATIONS
ProChem Double pH/ORP
PRO-CHEM-DPHRXG
Pause – Supply
Automatic
220-240 VAC 50-60 Hz
28 Watt
± 0.1 pH; ±10mV; ±1°C
±0.02pH, ±3mV; ±0.5°C
0-14pH; -99 -1000mV; 0...+55°C
1.5 l/h
1.5 bar
250 Vac 10A (resistive load)
500 mA (timed)
2.5 Kg
212 x 303 x 113 mm
ProChem Double | pH · ORP · Chlorine
Only use spare parts supplied by Hayward brands ®
220 Vac 50 Hz
Circulation pump
Do not use the Trigger cable to the circulation
pump if the SVP (speed variable pump) is
present, but use the Flow check sensor, pay
attention to disable or enable the function in
the setting menu.
ProChem Double pH/ORP/Chlorine
PRO-CHEM-DPHCL / PRO-CHEM-DPHCL2
Pause – Supply
Automatic
220-240 VAC 50-60 Hz
28Watt
± 0.1 pH; ±10mV; 0.1 ppm; ±1°C
±0,02pH, ±3mV; 0,05 ppm; ±0,5°C
0-14pH; -99 -1000mV; 0-5 ppm; 0...+55°C
4 l/h
1.5 bar
250 Vac 10A (resistive load)
500 mA (timed)
2.5 Kg
212 x 303 x 113 mm
Page 12 on 42
Flow check sensor