Hose replacement procedure
Open the pump's lid and release
the hose by pulling the left
connector upward.
Position the roller at 7h05, turning
it in the direction of the circular
arrow.
Storing the pump after use
Position the roller at 7h05, turning
it in the direction of the circular
arrow.
Insert the left connector into the
relative housing and pass the
hose under the roller's guide.
Turn the roller in the direction of
the circular arrow, simultaneously
accompanying the hose into
the pump's head, until the right
connector is reached.
When the regulation device must be stored, clean water should be pumped
through the hose in order to rinse it.
Then position the roller at 7h05, turning in the direction indicated by the circular arrow.
These two precautions will facilitate the subsequent reactivation of the unit.
ProChem Double | pH · ORP · Chlorine
Only use spare parts supplied by Hayward brands ®
Completely
connector, holding it taut towards
the outside, and turn the roller in
the direction of the circular arrow
so that the hose is freed up to the
right connector.
Close the pump's lid and press its
surface hard so that it is properly
locked into place.