6g. Temperature probe calibration
Always begin the calibration procedure with a calibration reset.
6h. Flow Rate Sensor Calibration
Note: before running the calibration routine check the water meter setting parameters in the Advanced Features menu.
Select into calibration Menu Flow Rate sensor, and set Flow
rate, to run the calibration routine.
Note: in the menu it is present Cal.Reset Item to erase the
last calibration and reload default parameters.
Check the Water meter is stopped, and the flow rate is sta-
tionary.
Press enter to start the counting pulse
Open the flow rate in the Water meter, the unit count the
pulses.
Set the volume liter to count with water meter and press
enter to save
ProChem Double | pH · ORP · Chlorine
Only use spare parts supplied by Hayward brands ®
Flow rate sensor
■ Flow rate
■ Cal. Reset
Calibration Flow Rate
Enter to confirm
Enter to confirm
Pulses: 00000
Liters: 00001
Page 30 on 42