EN
Password menu
Set the value for password, other than 0000.
Scroll through the menu using
Note: To remove the password set four zeros (0000) and press
Set a password for CAL menu
Enable= access password required
Disable= no need access password required
Set a password for SETUP menu
Enable= access password required
Disable= no need access password required
C. Advanced Features
• Temperature Measure
• Flow Rate Sensor
• Reed Input
• Pump Mode
• WiFi Info
• Power On Delay
• Flow Delay
• Circulation Pump
Below are illustrated the settings required for each sub-menu indicated
above.
Temperature Measure
Selection: Manual or automatic value
Manual value: please set fi xed value
and select the next item using
ProChem Double | pH · ORP · Chlorine
Only use spare parts supplied by Hayward brands ®
.
to confi rm.
Page 23 on 42
Set password
0 0 0 0
CAL Menu
□ Disable
■ Enable
SETUP Menu
□ Disable
■ Enable
Advanced Features
■ Temp. Measure
□ Flow Rate Meas.
□ Reed in
N. Open
□ Pump Mode
□ WiFi Info
□ P.ON Delay
OFF
□ Flow Delay
OFF
□ Circ. Pump
ON
Temp. Measure
□ Selection
Manual
■ Manual
25°C