Flow Delay
Setting time of Flow Delay routine, it is function with countdown timer to disable
the measure and dosing regulation when the fl ow rate is present again, to
ensure the right polarization of the probes
Set timer (range 0..60 minutes)
Timer= 0 minutes the function is disable
Circulation pump
Enable/ Disable trigger input of circulation pump, to enable or disable the dosing
system.
D. System Reset menu
• Reset unit: reload default parameters.
E. Firmware Revision menu
• Revision: show the firmware revision.
F. Control Panel menu
• Measure input
• Digital input
• Counters
ProChem Double | pH · ORP · Chlorine
Only use spare parts supplied by Hayward brands ®
Flow Delay
Circulation pump
□ OFF
■ ON
System Reset
FW Revision
FW Revision 1.0
Control Panel
■ Measure input
□ Digital input
□ Counters
Page 25 on 42