PRO-CHEM-DPHCL2 · ProChem Double pH / ORP / CL-Membrane installation layout
Warning!
Use with salt chlorinator:
For the pH systems, to prevent the risk of system malfunctioning or damage, observe the following instructions:
1. Position the pH measuring probe prior to the chlorinator cell.
2. To eliminate eddy currents, connect the pool water to an electrical ground point
3. Position the product injection point after the chlorinator cell.
3b. Wall-mounted installation
Mount the control box on the wall. The box must be installed in the equipment room (dry, temperate, ventilated). Caution,
acid vapours can cause irreversible damage to your device. Position the treatment product tanks accordingly.
Unplug the pool filter pump before you begin the installation. The installation must be performed in compliance with the
regulations in effect in the country of installation.
10
2
3
ProChem Double | pH · ORP · Chlorine
Only use spare parts supplied by Hayward brands ®
7
4
5
Make sure that the injection pressure is below 1.5 bar
1. Pool
2. Circulaton pump
8
3. Acid
9
4. Chlorine
5. Filter
6. Heat exchanger
7. ORP probe
8. pH probe
9. Cl-Mem probe
10. Temperature sensor
6