EN
Alarm
Level
Out of Range measure
OFA First Alarm
(time >70%)
OFA Second Alarm
(time 100%)
Flow Rate
Calibration Function
System Error
Alarm measure (*1)
(*1 Measure alarm Ranges)
n
Item
1
Temp. Measure min
2
Temp. Measure Max
3
pH Measure
min
4
pH Measure
Max
5
ORP Measure min
6
ORP Measure Max
Display
Level_____7.2_pH
Level_____750_mv
Level_____1.2_ppm
pH high, pH low
RX high, Rx low
CL high, CL low
OFA_Alr_7.2_pH
OFA_Alarm blinking
OFA_STOP_7.2_pH
OFA_STOP
Flow_OFF
Error_____7_pH
Error_____4_pH
Error_____465_mV
ParameterS error
High Measure
Low Measure
Limits
+ 10°C
+ 38°C
6 pH
8 pH
+450 mV
+850 mV
ProChem Double | pH · ORP · Chlorine
Only use spare parts supplied by Hayward brands ®
9. ALARMS
Actions to do
- Restore Product tank
- Replace or check the measure probe
- Restore measure
- Push
to reset
- Push
to reset
- Restore Flow Rate
- Restore Probe or Buff er solution and repeat calibration
procedure
- Press
to restore Default parameter
- Broken Unit
- Adjust the chemical concentration
PRO-CHEM-DPHCL
CL Measure: Min / Max
0 - 5 ppm = 0,5 - 4 ppm
PRO-CHEM-DPHCL2
CL Measure: Min / Max
0 - 2 ppm = 0,2 - 1,8 ppm
0 - 5 ppm = 0,5 - 4 ppm
0 - 10 ppm = 0,5 - 8 ppm
Page 36 on 42