EN
Setpoint = 7.4 pH
Dosing mode = Acid
(Prop. Band= 1.0 pH )
Dosing Period= 10 minutes
Acid Dosing method
SetPoint = 700 mV
Dosing mode = Low
(Prop.Band= 250mV)
Dosing Period= 10 minutes
Rx+ (Low) dosing method to add chlorine by
ORP measure
SetPoint =1.2ppm free Chlorine
Dosing mode = Low
(Prop. Band: 0.8ppm)
Dosing Period= 10 minutes
CL+ (Low) dosing method to add chlorine
ProChem Double | pH · ORP · Chlorine
8. DOSING METHOD
Alcalin Dosing method
Rx- (High) dosing method to add chlorine by
ORP measure
CL- (High) dosing method to reduce chlorine