A. pH Pump menu
• SetPoint: Chemical value to maintain into the process
• SetPoint Type:
Acid: the pump doses acid product to reduce pH value
Alca: the pump doses alkaline product to increase pH value
• OFA: Over feed alarm timer, maximum activation time
In Advanced menu-> Advanced features
• Time ON: Off..5" to 360" (Default Time ON: 180'') (*)
• Time OFF: Off..5" to 360" (Default Time OFF: 360'') (*)
Notes:
(*) Time ON and OFF are present if set Type dosing = Timed.
Time OFF value must be equal to or greater than Time ON.
B. ORP Pump menu
• SetPoint: Chemical value to maintain into the process
• SetPoint Type:
Rx+: the pump doses chlorine product and increase ORP
Rx-: the pump doses no chlorine product and reduce ORP
• OFA: Over feed alarm timer, maximum activation time
In Advanced menu-> Advanced features
• Time ON: Off..5" to 360" (Default Time ON: 180'') (*)
• Time OFF: Off..5" to 360" (Default Time OFF: 360'') (*)
Notes:
(*) Time ON and OFF are present if set Type dosing = Timed.
Time OFF value must be equal to or greater than Time ON.
C. CL Pump menu
• SetPoint: Chemical value to maintain into the process
• SetPoint Type:
Cl+: the pump doses chlorine product and increase value
Cl-: the pump doses no chlorine product and reduce value
• OFA: Over feed alarm timer, maximum activation time (range:1-240 min)
In Advanced menu-> Advanced features
• Time ON: Off..5" to 360" (Default Time ON: 180'') (*)
• Time OFF: Off..5" to 360" (Default Time OFF: 360'') (*)
Notes:
(*) Time ON and OFF are present if set Type dosing = Timed.
Time OFF value must be equal to or greater than Time ON.
ProChem Double | pH · ORP · Chlorine
Only use spare parts supplied by Hayward brands ®
pH Pump
■ SetPoint
■ SP Type
■ OFA
■ Time On
■ Time Off
■ min Alarm
■ Max Alarm
ORP Pump
■ SetPoint
■ SP Type
■ OFA
■ Time On
■ Time Off
■ min Alarm
■ Max Alarm
CL Pump
■ SetPoint
■ SP Type
■ OFA
■ Time On
■ Time Off
■ min Alarm
■ Max Alarm
Page 20 on 42
7.40pH
Acid
00'
180''
360''
6 pH
8 pH
740mV
Low
00'
180''
360''
450 mV
850 mV
1.20ppm
Low
00'
180''
360''
0.5 ppm
2.0 ppm