7.9 Open the Axon-Bus Gripping Component in an Emergency

8 Maintenance

8.1 Service Information

Since all moving mechanical parts are subject to wear and tear, regular service is required within
the guarantee period. In the course of service, Ottobock Service (Ottobock Myo-Service) checks
the entire product. Wear parts are replaced as required. Omitting a scheduled service inspection
voids the guarantee.

9 Legal information

9.1 Liability
Otto Bock Healthcare Products GmbH, hereafter referred to as manufacturer, assumes liability
only if the user complies with the processing, operating and maintenance instructions as well as
the service intervals. The manufacturer explicitly states that this device may only be used in com­
bination with components that were authorised by the manufacturer (see instructions for use and
catalogues). The manufacturer does not assume liability for damage caused by component com­
binations which it did not authorise. The device may only be opened and repaired by authorised
Ottobock technicians.

9.2 Trademarks

All product names mentioned in this document are subject without restriction to the respective
applicable trademark laws and are the property of the respective owners.
All brands, trade names or company names may be registered trademarks and are the property of
the respective owners.
Should trademarks used in this document fail to be explicitly identified as such, this does not justi­
fy the conclusion that the denotation in question is free of third-party rights.
9.3 CE Conformity
This product meets the requirements of the European Directive 93/42/EEC for medical devices.
This product has been classified as a class I device according to the classification criteria out­
lined in Annex IX of the directive. The declaration of conformity was therefore created by the man­
ufacturer with sole responsibility according to Annex VII of the directive.
The product meets the requirements under the RoHS Directive 2011/65/EU of the European Par­
liament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous sub­
stances in electrical and electronic equipment.
This safety function allows the Axon-Bus gripping component to be
opened regardless of the control signals present.
1) With the Axon-Bus prosthetic system switched on, press the char­
ging receptacle button and hold for approximately three seconds
until the Axon-Bus gripping component begins to open. A pulsating
beep sounds as it opens.
2) Releasing the button immediately stops the process of opening the
Axon-Bus gripping component and turns the entire Axon-Bus pros­
thetic system off.