De-rates are referenced to the Max Continuous Torque ΔT wdg. = 100°C
Options - Brake
Resolver
98.9%
Resolver/Seal
97.1%
SFD
98.9%
SFD/Seal
97.1%
DSL
98.9%
DSL/seal
97.1%
EnDat2.2
95.8%
EnDat2.2/Seal
93.9%
Note: For EnDat feedback motors acceleration of the motor is limited to ≤1*10
servo drive may further limit this value.
0
1000
2000
3000
97.4%
95.4%
93.3%
95.5%
93.5%
91.4%
97.4%
95.4%
93.3%
95.5%
93.5%
91.4%
97.4%
95.4%
93.3%
95.5%
93.5%
91.4%
93.8%
91.3%
88.6%
91.7%
88.7%
85.6%
AKM2G Instructions | 7 Technical Data
Speed: RPM
4000
5000
6000
91.2%
89.0%
86.7%
89.2%
87.0%
84.5%
91.2%
89.0%
86.7%
89.2%
87.0%
84.5%
91.2%
89.0%
86.7%
89.2%
87.0%
84.5%
85.8%
82.9%
79.8%
82.4%
79.0%
75.4%
Kollmorgen | kdn.kollmorgen.com | August 2020
7000
8000
84.4%
81.9%
81.1%
77.6%
84.4%
81.9%
81.1%
77.6%
84.4%
81.9%
81.1%
77.6%
76.6%
73.2%
71.6%
67.5%
5
rad/s
2
. The connected
185