Guide For Electrical Installation; Connection Of The Motors With Preassembled Cables - Kollmorgen AKM2 Serie Manual De Instrucciones

Ocultar thumbs Ver también para AKM2 Serie:
Tabla de contenido

Publicidad

AKM2G Instructions | 1   English

1.6.2 Guide for electrical installation

Check that the servo amplifier and motor match each other. Compare the rated voltage and rated
l
current of the unit. Carry out the wiring according to the wiring diagram in the instructions
manual of the servo amplifier. The connections to the motor are shown in chapter "Connector
Pinout" from
Install all cables carrying a heavy current with an adequate cross-section, as per EN 60204. The
l
recommended cross-section can be found in the Technical data.
In case of  long motor cables (>25m) and dependent on the type of the used servo
amplifier a motor choke must be switched into the motor cable (see instructions
manual of the servo amplifier and accessory manual).
Ensure that there is proper earthing of the servo amplifier and the motor. Use correct earthing
l
and EMC-shielding according to the instructions manual of the servo amplifier which is used.
Earth the mounting plate and motor casing.
If a motor power cable is used which includes integral brake control leads, then these brake
l
control leads must be shielded. The shielding must be connected at both ends (see instructions
manual of the servo amplifier).
Cabling:
l
Route power cables as separately as possible from control cables
l
Connect the feedback device.
l
Connect the motor cables, install motor chokes (if applicable) close to the amplifier
l
Connect shields to shielding terminals or EMC connectors at both ends
l
Connect the holding brake, if used
l
Connect shielding at both ends.
l
Connect up all shielding via a wide surface-area contact (low impedance) and metallized connector
l
housings or EMC-cable glands.
Requirements to cable material:
l
Capacitance
Motor cable: less than 150 pF/m
Feedback cable: less than 120 pF/m

1.6.3 Connection of the motors with preassembled cables

Carry out the wiring in accordance with the valid standards and regulations.
l
Only use Kollmorgen preassembled shielded cables for the feedback and power connections.
l
Incorrectly installed shielding leads to EMC interference and has an adverse effect on system
l
function.
The maximum cable length is defined in the instructions manual of the used servo amplifier.
l
For a detailed description of configured cables, please refer to the regional
accessories manual.
24
Kollmorgen | kdn.kollmorgen.com | August 2020
Connector
Pinout.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Akm2g2Akm2g3Akm2g4Akm2g5Akm2g6Akm2g7

Tabla de contenido