AKM2G Instructions | 7 Technical Data
De-rates are referenced to the Max Continuous Torque ΔT wdg. = 100°C
Options - Brake
Resolver
Resolver/Seal
SFD
SFD/Seal
DSL
DSL/Seal
EnDat2.2
EnDat2.2/Seal
Note: For EnDat feedback motors acceleration of the motor is limited to ≤1*10
servo drive may further limit this value.
280
Kollmorgen | kdn.kollmorgen.com | August 2020
0
1000
2000
98.2%
93.6%
88.0%
96.9%
91.4%
84.6%
98.2%
93.6%
88.0%
96.9%
91.4%
84.6%
98.2%
93.6%
88.0%
96.9%
91.4%
84.6%
98.2%
93.6%
88.0%
96.9%
91.4%
84.6%
Speed: RPM
3000
4000
82.4%
77.0%
77.7%
70.7%
82.4%
77.0%
77.7%
70.7%
82.4%
77.0%
77.7%
70.7%
82.4%
77.0%
77.6%
68.7%
5
rad/s
5000
6000
71.5%
66.2%
63.5%
56.2%
71.5%
66.2%
63.5%
54.3%
71.5%
66.2%
63.5%
54.3%
71.0%
64.5%
59.3%
49.3%
2
. The connected