7.5.4 Technical Data AKM2G-54
U
Parameter
N
Max. Rated Equivalent Line Voltage
Max. Continuous Torque for ∆ T
winding = 100°C (1)(2)(4)
Max. Continuous Current for ∆ T
winding = 100°C (1)(2)(4)
Max. Continuous Torque for ∆ T
winding = 60°C (2)(4)
Max. mechanical speed (5)
Peak Torque (1)(2)(4)
Peak Current
120 V
Rated Torque (speed) (1)(2)(4)
AC
Rated Speed
Rated Power (speed) (1)(2)(4)
240 V
Rated Torque (speed) (1)(2)(4)
AC
Rated Speed
Rated Power (speed) (1)(2)(4)
400 V
Rated Torque (speed) (1)(2)(4)
AC
Rated Speed
Rated Power (speed) (1)(2)(4)
480 V
Rated Torque (speed) (1)(2)(4)
AC
Rated Speed
Rated Power (speed) (1)(2)(4)
AKM2G Instructions | 7   Technical Data
Tolerance Symbol
Electrical data
Max
V bus
Nom
Tmc
Nom
Imc
Nom
Tmc
Nom
Nmax
Nom
Tp
Nom
Ip
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Kollmorgen | kdn.kollmorgen.com | August 2020
Units
AKM2G
54L
54M
V ac
480
480
Nm
20.1
20.0
ib-in
178
177
Arms
10.6
14.6
Nm
15.9
15.9
lb-in
141
141
rpm
6000 6000 6000
Nm
54.8
54.7
lb-in
485
484
Arms
31.7
43.9
Nm
19.3
lb-in
171
rpm
1100 1200
kW
2.22
Hp
2.98
Nm
18.4
17.2
lb-in
163
152
rpm
1600 2300 2600
kW
3.09
4.13
Hp
4.14
5.54
Nm
15.9
12.9
lb-in
141
114
rpm
2800 3900 4500
kW
4.66
5.28
Hp
6.25
7.08
Nm
14.3
9.80
lb-in
126
86.7
rpm
3400 4800
kW
5.08
4.92
Hp
6.81
6.60
54N
400
20.0
177
16.3
15.9
141
54.7
484
48.8
19.1
169
2.40
3.22
16.5
146
4.49
6.02
11.0
97.6
5.20
6.97
291