AKM2G Instructions | 7 Technical Data
7.4.8 Technical Data AKM2G-44L
U
Parameter
N
Max. Rated DC Bus Voltage
Max. Continuous Torque for ∆ T
winding = 100°C (1)(2)(4)
Max. Continuous Current for ∆ T
winding = 100°C (1)(2)(4)
Max. Continuous Torque for ∆ T
winding = 60°C (2)(4)
Max. mechanical speed (5)
Peak Torque (1)(2)(4)
Peak Current
24 V
Rated Torque (speed) (1)(2)(4)
DC
Rated Speed
Rated Power (speed) (1)(2)(4)
48 V
Rated Torque (speed) (1)(2)(4)
DC
Rated Speed
Rated Power (speed) (1)(2)(4)
72 V
Rated Torque (speed) (1)(2)(4)
DC
Rated Speed
Rated Power (speed) (1)(2)(4)
96 V
Rated Torque (speed) (1)(2)(4)
DC
Rated Speed
Rated Power (speed) (1)(2)(4)
272
Kollmorgen | kdn.kollmorgen.com | August 2020
Tolerance Symbol
Electrical data
Max
V bus
Nom
Tmc
Nom
Imc
Nom
Tmc
Nom
Nmax
Nom
Tp
Nom
Ip
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Units
AKM2G
LL
ML
V dc
170
170
Nm
8.59
8.60
ib-in
76.0
76.1
Arms
12.8
14.5
Nm
6.70
6.71
lb-in
59.3
59.4
rpm
6000 6000 6000
Nm
27.1
27.1
lb-in
240
240
Arms
51.3
58.2
Nm
8.54
lb-in
75.6
rpm
500
kW
0.447 0.534
Hp
0.600 0.716
Nm
8.46
8.41
lb-in
74.9
74.4
rpm
700
900
1000
kW
0.620 0.793 0.875
Hp
0.832 1.06
Nm
8.35
8.29
lb-in
73.9
73.4
rpm
1000 1200 1400
kW
0.874 1.04
Hp
1.17
1.40
Nm
8.28
8.21
lb-in
73.2
72.6
rpm
1200 1400 1600
kW
1.040 1.20
Hp
1.39
1.61
NL
170
8.59
76.0
16.4
6.70
59.3
27.1
240
65.7
8.50
75.2
600
8.36
74.0
1.17
8.20
72.5
1.20
1.61
8.11
71.7
1.36
1.82