Acknowledge fault

General
6.0.0.0
E000
6.0.0.0
10
1/1
Fig. 45: Navigation in the event of an error
118
E000
5.0.0.0
S
You can check this by disconnecting all the communication lines
installed by the customer from the electronic module. If the error no
longer occurs, there could be an external interfering signal on the
communication line(s) that exceeds the applicable standard values.
The pump can only return to normal operation once the source of
interference is remedied.
In the event of an error, the error page is displayed instead of the
status page.
In this case, the following procedure can generally be used for
navigation (Fig. 45):
• To change to the menu mode, press the white button.
Menu number <6.0.0.0> flashes on the display.
By turning the white button, it is possible to navigate in the menu as
usual.
• Press the white button.
Menu number <6.0.0.0> appears steady on the display.
On the units display, the current incidence (x) as well as the maximum
incidence of the error (y) are displayed in the format "x/y".
Until the error can be acknowledged, pressing the white button again
will cause a return to menu mode.
NOTE:
A 30-second time-out causes the display to revert to the status page
or error page.
NOTE:
Each error number has a separate error counter that counts incidences
of the error within the last 24 hours. The error counter is reset after
manual acknowledgement, 24 hours after "Mains on" or after a
repeated "Mains on".