5.2

Technical data

Property
Speed range
Nominal diameters DN
Pipe connections
Permissible min./max. fluid temperature
Ambient temperature min./max.
Storage temperature min./max.
Maximum permitted operating pressure
Insulation class
Protection class
Electromagnetic compatibility
Emitted interference in acc. with
Interference resistance in acc. with
Sound-pressure level
2)
Permissible fluids
Electrical connection
Internal electric circuit
Speed control
Relative humidity
- at T
= 30 °C
ambient
- at T
= 40 °C
ambient
1)
Average value of the sound-pressure level at a spatially rectangular measuring surface at a distance of 1 m from the pump surface in accordance with
DIN EN ISO 3744.
2)
For more information about permissible fluids, see the "Fluids" section on the next page.
Table 1: Technical data
Fluids
70
Value
750 – 2900 min
380 – 1450 min
SIE/DIE:
40/50/65/80/100/125/150/200 mm
PBE:
32/40/50/65/80/100/125 mm (pressure
side)
Flanges PN 16
-20 °C to +140 °C
0 to +40 °C
-20 °C to +60 °C
16 bar
F
IP 55
EN 61800-3
EN 61800-3
1)
L
Heating water according to VDI 2035
Cooling/cold water
Water/glycol mixture up to 40% vol.
Heat transfer oil
Other fluids
3~380 V -5%/+10%, 50/60 Hz
3~400 V ±10%, 50/60 Hz
3~440 V ±10%, 50/60 Hz
PELV, galvanically isolated
Built-in frequency converter
< 90%, non-condensing
< 60%, non-condensing
• The fluid must be sediment-free.
• Salmson's approval must be obtained for the use of other fluids.
• Mixtures with a proportion of glycol of > 10% influence the p-v
• In systems built according to the state of the art, it can be assumed
-1
-1
< 83 dB(A) | ref. 20 Pa
pA, 1m
If water/glycol mixtures are used (or fluids with a viscosity other than
that of pure water), an increase in power consumption of the pump is
to be taken into account. Only use mixtures with corrosion inhibitors.
The respective manufacturer's instructions are to be observed!
pump curve and the flow calculation.
under normal system conditions that the standard seal/standard
mechanical seal is compatible with the fluid. Special circumstances
(e.g. solid material, oils or EPDM-corrosive substances in the fluid, air
in the system etc.) may require special seals.
Remarks
Depending on pump type
EN 1092-2
Depending on fluid
Lower or higher ambient
temperatures on request
Residential
Industrial
Depending on pump type
Standard version
Standard version
Standard version
Only for special version
Only for special version
Supported mains types:
TN, TT
Salmson 12/2017