1.11 NOISE LEVEL

PONYBENCH BTPLUS's noise level was measured with the control pumps operating, load-free under normal operating
conditions. Measurements were taken to conform to EN ISO 3746/1996 standard by a competent laboratory using a
precision integrating phonometer. The test results are indicated below:
Average sound pressure level LpAm
Sound pressure at operator's post LpA
Sound power level LwA

1.12 TECHNICAL SPECIFICATIONS

The essential data are shown in the table. For more detailed information on product characteristics, contact the
manufacturer directly.
SPECIFICATION
Max. capacity of lift without pull system
Max. capacity of lift equipped with pull arm
Max. height (without pads)
Length of upper mobile platform
Width of upper mobile platform
Length of base frame
Width of base frame
Operating pressure of lift hydraulic circuit
Operating pressure of pull arm pump hydraulic circuit
Operating pressure of pneumatic supply circuit
Weight of lift complete with accessories without pull system
Weight of standard pull arm with accessories
Ascent time
Descent time
Three-phase power supply version
Single-phase power supply version
Power supply frequency
Three-phase electric motor power
Auxiliary circuit voltage with 400 V three-phase power supply
Auxiliary circuit voltage with 230 V single-phase power supply
Control unit weight
Weight of lift complete with accessories and pull system
dB(A)
dB(A)
dB(A)
60
PONYBENCH BTPLUS
MEASURE
VALUE
kg
3000
kg
2700
mm
1420
mm
2210
mm
700
mm
2185.5
mm
630
bar
270
bar
500
bar
8
kg
610
kg
172
sec
46
sec
49
volt
400 A.C.
volt
230 A.C.
hertz
50
kW
1.5
volt
24 A.C.
volt
230 A.C.
kg
50
kg
782
68.1
88.3
78.4