enter <P4 DEVICES> menu
-
enter menu group: <P4.1 COMPUTER>
-
select port to which a computer is to be connected,
-
COM 1 or COM 2 – RS 232 port, to which the computer is connected
USB 2 type B – USB port, to which the computer is connected
USB FREE LINK – USB type B port, to which the computer is connected. The tool, acting
like a keyboard, is used for entering data for peripherals. On proper modification of non-
standard printout and sending proper command from the computer or on pressing
ENTER on balance's keyboard, the data from non-standard printout is directly entered to
computer programs, e.g. Excel, Word, Notepad etc.
Press <USB FREE LINK>
cooperation with computer programs:
SPREAD SHEET – value YES - cooperation with Excel type program,
DELAY – if any 'looses' of transferred information occur (caused by data auto-entering or
auto-formatting by computer program) during cooperation with Excel type program,
parameter value should be set to <2>. If the 'looses' still occur, parameter value should
be higher. The user can change parameter's value ranging from 0 (quick data transfer) to
9 (slow data transfer – around 10 characters per second).
WIFI – WIFI port

13.1.2. Continuous Transmission

Continuous
transmission
a measurement result.
Available options:
Continuous transmission in a calibration unit <CAL. UNIT>, independently from currently
chosen weight unit, measurements are transmitted in unit set on a main measuring device
(calibration unit)
Continuous transmission in a current unit <CURRENT UNIT> measurements are transmitted in
a current unit; the unit changes dynamically whenever the user presses Units button in order to
modify the unit on a display.
Continuous transmission off <NONE>
Procedure:
CAUTION!
Continuous transmission may be turned on/off by means of a command sent from a computer (go to
COMMUNICATION PROTOCOL section)

13.1.3. Printouts Interval for Continuous Transmission

Parameter <P4.1.3. INTERVAL> enables setting frequency of printouts for continuous transmission.
Frequency of printouts is set in seconds, wherein the accuracy is 0.1s.
The user may set any time value ranging from 1000 to 0.1 s.
and configure port settings to enable balance correct
- value NO – cooperation with other programs,
parameter