QUICK START
UNITS
Setpoint
TEMPERATURE
PRESSURE
FLUID LEVEL
AUTO REFILL*
FLOW*
Line Frequency*
60HZ
Auto Restart
Audible Alarms
RA FAN SPEED MODE*
Care Level
SERIAL COMM - DCOM*
ANALOG COMM - ACOM*
RESISTIVITY*
mm/dd/yy
hh:mm:ss
Quick Start Done
NOTE Any setting can be changed
lines of the QUICK START menu at
Use the down arrow to scroll
through and highlight each line.
If a change to any of the default
settings is needed, with the
desired line highlighted press the
enter button.
Once the desired value is displayed,
all the desired changes are made
display a fault message and, if en-
Lines that are not all capital letters
indicate the changes can be made
directly on the QUICK START menu
Use the same procedure to change
Display
Indication
UNITS
Controller temperature, pres-
(Flow display is optional.)
Setpoint
TEMPERATURE
20
PRESSURE
(The delay sets the length of time
needed after a pressure fault before
the chiller shuts down.)
off
1
FLUID LEVEL
AUTO REFILL
(On is the % of fluid level in the
reservoir needed to turn refill on.
Time Out is the maximum time the
option will operate. Setting the time
to 0 disables the option.)
FLOW
Line Frequency
The incoming frequency
(Chillers with a P 3 - P 5 pump and
the capability to run on either 50
Hz or 60 Hz only. The selected
frequency automatically adjusts
the firmware's fixed high pressure
default setting.)
Auto Restart
Audible Alarms
RA FAN SPEED
MODE
air-cooled chillers only
(Auto allows the fan to run under
the conditions listed in the manual,
see Section 3. On allows the fan to
run at high speed all the time.)
Care Level
The preventive care cleaning
frequency reminder for the
SERIAL COMM
Optional serial communica-
- DCOM
information.)
ANALOG COMM
Optional analog communica-
-
- ACOM
information.)
RESISTIVITY
for additional information.)
-
mm/dd/yy
hh:mm:ss
Quick Start Done To end the quick start procedure and save changes press the enter
Table 1
Fault Range
T0 T1 P1 P2 Pumps: 3 to 105 PSI
T5 Pumps:
2 to 105 PSI
P3 P4 P5 Pumps:
See Manual
Table 2
Range
T0 T1 P1 P2 Pumps: 0.0 to 10.5 GPM 0.0 GPM
-
T5 Pumps:
0.0 to 15.0 GPM 0.0 GPM
P3 P4 P5 Pumps:
0.0 to 30.0 GPM 0.0 GPM
Range
C or F
psi, bar or kPa
gpm or lpm
+5°C to +40°C
(+5°C to +90° for
high temp chillers)
-
+2°C to +43°C
(+93°C for high
temp chillers)
Pump dependent
- refer to Table 1
Time Delay:
0 to 30 seconds
Heater depen-
dent - refer to
Table 3
On: 70%- 100%
Time Out: 0 - 900
seconds
Pump dependent
- refer to Table 2
50 Hz or 60 Hz
or
or
On or Auto
off, 1 (1000 hours),
2 (2000 hours)
3 (3000 hours)
off, RS232,
RS485
(See manual for additional
Refer to manual
(See manual for additional
or
Setpoint:
(See manual
Interval:
Warning High:
Table 3
High Default
Low Default
105 PSI
3 PSI
Heater
None
105 PSI
4 PSI
See Manual
4 PSI
1 kW:
2.3 kW:
High Default
Low Default
5.0 kW:
4.6 kW:
0.0 GPM
0.0 GPM
Heater
0.0 GPM
None
1 kW:
2.3 kW:
5.0 kW:
4.6 kW:
Default
C
psi
gpm
+20°C
High +42°C
(+92°C for high
temp chillers)
Pump dependent
- refer to Table 1
High Time Delay:
0 seconds
(60 seconds for
P3 - P5 pumps)
10 seconds
Heater depen-
dent - refer to
Table 3
Heater depen-
dent, see manual
Pump dependent
- refer to Table 2
60 Hz
Auto
off
off
off
Setpoint:
Interval:
Warning High:
Warning Range
Default
6 - 100%
6%
58 - 100%
58%
58 or 69 - 100%
58 or 69%
87 - 100%
87%
87 - 100%
87%
Fault Range
Default
0 - 100%
0%
52 - 100%
52%
52 or 63 - 100%
52 or 63%
81 - 100%
81%
81 - 100%
81%