UL Markings
Use 60°C or 75°C copper wire only for every model of this section.
}
Use Class 1 wire only.
}
Tightening torque for field wiring terminals:
}
X0, X8, X9: 0.7 - 0.8Nm (6.20 to 7.08 lbf in)
Use in a pollution degree 2 environment.
}
These devices provide solid state motor overload protection at 130% of full load cu-
}
rrent.
Integral solid state short circuit protection does not provide branch circuit protection.
}
Branch circuit protection must be provided in accordance with the National Electrical
Code and any additional local codes.
These devices are not provided with motor over-temperature sensing.
}
Suitable for use on a circuit capable of delivering not more than 42kA rms symmetrical
}
amperes for a max. voltage of 480 Vac.
Supply circuit protection:
}
Model
PMCprotego D.01
PMCprotego D.03
PMCprotego D.06
PMCprotego D.12
PMCprotego D.12 P
PMCprotego D.24
PMCprotego D.24 P
The drives may be connected together via the "common bus" (DC bus link) based on
}
the instructions on p. 70ff. The devices may also be grouped from the AC input side ba-
sed on the max. input fuse (e.g. 3 pcs. PMCprotego D.01 with one common 6A fuse in
line).
3.1.5
Función de seguridad STO
La función de seguridad "Par con desconexión segura" (Safe Torque Off, STO) activa el
bloqueo de impulsos del servoamplificador e interrumpe la alimentación del motor. Cumple
los requisitos según EN 61800-5-2.
Las entradas STO1-ENABLE y STO2-ENABLE corresponden, en
control monocanal sin realimentación, a los requisitos según EN ISO 13849-1: PL d
}
(cat. 2) y EN/IEC 62061: SIL CL 2.
control bicanal con realimentación, a los requisitos según EN ISO 13849-1: PL e (cat.
}
4) y EN/IEC 62061: SIL CL 3.
Manual de instrucciones PMCprotego D.01 ... D.24
21934-ES-08
Fuse class
RK5, CC, J, T
RK5, CC, J, T
RK5, CC, J, T
RK5, CC, J, T
RK5, CC, J, T
Rating
Max. Fuse Rating
600 VAC 200 kA
6 A (Time delay)
600 VAC 200 kA
6 A (Time delay)
600 VAC 200 kA
10 A (Time delay)
600 VAC 200 kA
15 A (Time delay)
600 VAC 200 kA
30 A (Time delay)