Descargar Imprimir esta página

Siemens SINAMICS G130 Manual De Listas página 1017

Ocultar thumbs Ver también para SINAMICS G130:

Publicidad

n_limit pos eff
r1084
[3050.8]
n_limit neg eff
<5> [3095.7]
r1087
n_act smooth
r0063
n_act smooth signal
[4710.7]
<5>
r2169
0...1 000 000 ms
[8011.1]
p2153 (0)
[8012.5]
[8013,1]
n_act unsmoothed
r0063[0]
[4715.7]
<4>
Smoothing
<1> VECTOR: Calculated.
<2> VECTOR:
Depending on the drive unit (250 or 400 μs).
<3> VECTOR:
Depending on the drive unit (1000 or 1600 μs).
<4> Only for VECTOR.
<5> Only for SINAMICS S120 and SERVO.
1
2
DO: SERVO, VECTOR
Signals and monitoring functions - Speed signals 1
0
n
n
F07901 "motor overspeed"
0.00...60 000.00 RPM
p2162[D] (600.00)
n_thresh val 3
0.00...210 000.00 RPM
p2161[D] (5.00)
1
0
0.00...300.00 RPM
p2150[D] (2.00)
n_hysteresis 3
n_thresh val 2
0.00...210 000.00 RPM
p2155[D] (900.00)
1
0
0.00...300.00 RPM
p2140[D] (90.00)
n_Hysterrese 2
<1>
3
4
p0115[1] (125.00 μs)
p0115[1] (<2>)
|n_act| > n_max
r2197.6
[2534.3]
[8021.1]
n_thresh val 1
0.00...210 000.00 RPM
p2141[D] (5.00)
1
1
0
0
0.000...300.000 RPM
p2142[D] (2.00)
n_hysteresis 1
<1>
5
6
Function diagram
fp_8010_54_eng.vsd
S120/S150/G130/G150
29.06.09 V04.03.01
p0115[3] (4000.00 μs)
p0115[3] (<3>)
|n_act| < p2161
r2199.0
[2537.3]
0...10 000 ms
p2156[D] (0)
f or n-comparison value
reached/exceeded
T
0
r2199.1
[2537.3]
|n_act|
p2155
r2197.1
[2534.3]
7
8
- 8010 -

Publicidad

loading

Este manual también es adecuado para:

Sinamics g150