Descargar Imprimir esta página

Siemens SINAMICS G130 Manual De Listas página 898

Ocultar thumbs Ver también para SINAMICS G130:

Publicidad

p1416
n_ctrl setp sum
r1170
[1550.8]
Droop input
p1488
[6030] Speed setpoint filter
[6031] Acceleration model
n_act unsmoothed
r0061[0]
encoder 1
p1300
(r1407.1)
n_model
<1>
[1710.1]
[4715] Speed actual value and pole position sensing motor encoder ASM/SM (encoder 1)
<1> Only for vector control without encoder.
1
2
DO: VECTOR
Overviews - Vector control, speed control and generation of the torque limits
[6050] Kp_n-/Tn_n adaptation
p0341
p0342
p1496
n_set after filter
n_ctrl n_set
r0062
Symmetrizing
r1438
n_set I_comp
r1439
Reference model
p1400.3
[6040] Speed controller
n_act smooth
r0063
3
4
Kp adaptation
Tn adaptation
p1460 p1470
p1462
p1472
<1>
<1>
p1501
Kp
p1503
Tn
Integrator control
M-max upper/mot
p1520
<1>
p1442
p1452
M-max lower/gen
p1521
p1300
(r1407.1)
<1>
n_pre-control [1710.1]
5
fp_1700_54_eng.vsd
19.01.09 V04.03.01
p1511
p0115[1] (Motor Modules)
For Kp
p0115[2] (Motor Modules)
p1512
adaptation
Refer to [1020.7]
p1514
p1513
r1515
r1518
p1540
p1300
(r1407.1)
p1508
p1541
[6060] Torque setpoint
I_outp max
p0640
r0067
p1522
Forming the
torque limits
p1523
p1530 p1531
[6630] Torque limit
[6640] Current-power limit
p1400
p1401
r0056
r1408
[6490] Closed-loop speed control configuration
[6491] Closed-loop flux control configuration
[2526] Status word closed-loop control
[2530] Status word closed-loop current control
6
7
Function diagram
S120/S150/G130/G150
M_set total
r0079
[1710.1]
M_max upper eff.
r1538
M_max lower eff.
r1539
8
- 1700 -