EN - 24
7.4. To RE-START the LAST CYCLE STARTED with the SAME SETTINGS
Press
for a long time: the display shows the label of the last cycle started.
Press
again: the display shows the duration of blast chilling in the case of a timed cycle (unit of measurement=min)
or the blast chilling end temperature in the case of a temperature cycle.
To modify the value, act on the
Press
to start the cycle.
7.5. INTERRUPTION of the POWER SUPPLY
During a power cut: the LED
To silence it, press any key.
If this occurs during:
timed blast chilling,
when the power supply is restored, blast chilling will re-start from the point when the power cut occurred. After the power
cut, the maximum blast chilling time increase is 10 min.
temperature blast chilling,
when the power supply is restored, blast chilling will start again from the beginning;
during preservation,
when the power supply is restored, blast chilling will start again in automatic mode.
7.6. DEFROSTING
With the appliance in stand-by manual defrosting can be activated by pressing the
Defrosting takes place with air and with the door open.
7.7. DISPLAY of the COMPRESSOR STATE and of the EVAPORATOR FAN
With no procedure in progress, by pressing the
DISPLAY THE STATE OF THE COMPRESSOR
- if the display shows "C-1", the compressor is on
- if the display shows "C-0", the compressor is off
- if the display shows "C-P", the compressor is switched-off.
With no procedure in progress, by pressing the
TO DISPLAY THE STATE OF THE EVAPORATOR FAN
- if the display shows "F-1", the evaporator fan is on
- if the display shows "F-0", the evaporator fan is off
- if the display shows "F-P", evaporator fan switch-on delay is in progress.
To exit the procedure, press
not operate.
or
key; the setting remains active until another cycle is selected.
is on and the buzzer rings.
key it is possible:
key twice it is possible:
several times until the display shows the specification for the state in progress or do
key for a prolonged time.