PARAMETER
MIN.
u 0
0
PARAMETER
MIN.
L A
1
L b
0
L P
0
PARAMETER
MIN.
E0
0
E9
0
(1) the unit of measurement depends on parameter P2
(2) set the parameters relating to the controllers appropriately after altering parameter P2
(3) the device stores the defrost interval count every 30 minutes; altering parameter d0 has effect of concluding the previous defrost inter-
val or manual defrost activation
(4) the temperature alarm functions are only enabled during storage operations
(5) the parameter differential is 2.0 ºC/4 ºF
(6) there are no temperature alarms during defrosting and drip draining, if they occur following defrost activation
(7) there is no maximum temperature alarm while microport input is enabled, if occurring after input activation
(8) the evaporator fan will be shut down providing defrosting is not ongoing
(9) the compressor and ventilator fan are shut down 10 s after input activation
MAX.
M.U.
DEF.
1
...
1
MAX.
M.U.
DEF.
247
...
247
3
...
2
2
...
2
MAX.
M.U.
DEF.
3
-
1
1
...
1
DIGITAL OUTPUTS
service controlled by relay K2
0 = defrosting
1 = evaporator fan
SERIAL NETWORK (MODBUS)
device address
baud rate
0 = 2.400 baud
1 = 4.800 baud
2 = 9.600 baud
3 = 19.200 baud
parity
0 = none (no parity)
1 = odd
2 = even
RESERVED
quantity modifiable quickly before starting the cycle
0 = no quantity
1 = with a timed chilling: the chilling duration
with a set-temperature chilling: the chilling end-point temperature
2 = with a timed chilling: the chilling duration and the chilling operational setpoint
with a set-temperature chilling: the chilling operational setpoint
3 = with a timed chilling: the chilling duration and the chilling operational setpoint
with a set-temperature chilling: the chilling end-point temp. and the chilling operational setpoint
reserved
29 - EN