Friulinox BF030AG Manual De Uso, Mantenimiento E Instalación página 28

Abatidor de temperatura

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN - 28
PARAMETER
MIN.
d 0
0
d 3
0
d7
0
PARAMETER
MIN.
A 1
0,0
A2
0
A 4
0,0
A 5
0
A 6
0
A 7
0
A 8
0
A 9
0
A A
0
PARAMETER
MIN.
F0
0
F 2
0
F8
0
PARAMETER
MIN.
i 0
0
i1
0
i 2
-1
i 3
-1
i 7
0
MAX.
M.U.
DEF.
99
h
0
99
min
8
15
min
2
MAX.
M.U.
DEF.
99,0
°C/°F (1)
10,0
1
...
0
99,0
°C/°F (1)
10,0
1
...
0
240
min
15
240
min
15
240
min
15
240
min
15
240
s
5
MAX.
M.U.
DEF.
2
...
1
2
...
2
99
min
0
MAX.
M.U.
DEF.
2
...
0
2
...
1
120
min
30
120
min
-1
120
min
0
DEFROST
defrost interval (3)
0 = regular periodic defrosting will never be enabled
defrost duration
0 = defrosting will never be enabled
drip-drain duration
TEMPERATURE ALARMS (4)
the temperature below which the minimum temperature alarm is activated;
see also A2 (5)
minimum temperature alarm type
0 = no alarm
1 = depending on parameters r9 and rA (or "r9 - A1" and "rA - A1")
the temperature above which the maximum temperature alarm is activated;
see also A5 (5)
maximum temperature alarm type
0 = no alarm
1 = depending on parameters r9 and rA (or "r9 + A4" and "rA + A4")
storage operation start-up temperature alarm delay
temperature alarm delay
drip-drain end maximum temperature alarm delay (6)
microport input deactivation maximum temperature alarm delay
(only if i0 = 0 or 1) (7)
blast chill completion buzzer duration
EVAPORATOR FAN (only if u0 = 1)
evaporator fan activity during chilling
0 = off
1 = on
2 = in parallel with the compressor
evaporator fan activity during storage
0 = off
1 = on
2 = in parallel with the compressor
evaporator fan start-up delay following defrost cycle start
DIGITAL INPUTS
digital input operation
0 = MICROPORT INPUT - in this case parameters i1, i2 and i3 assume significance; enabling input
will cause the evaporator fan to be shut down (at most for the period of time set by i3 or until
input will be disabled) (8) (9)
1 = MICROPORT INPUT - in this case parameters i1, i2 and i3 assume significance; enabling input
will cause the compressor and evaporator fan to be shut down (at most for the period of time set
by i3 or until input will be disabled) (8) (9)
2 = COMPRESSOR PROTECTION - in this case, parameters i1 and i7 assume significance; the
compressor will be shut-down, the display will flash code "iA" and the buzzer will be activated
(until the input will be deactivated)
digital input contact type
0 = NA (input active with contact closed)
1 = NC (input active with contact open)
2 = no input
microport input activation effect maximum duration (only if i0 = 0 or 1)
-1 = the effect will last until the input will be disabled
durata massima dell'effetto provocato dall'attivazione dell'ingresso micro porta (solo se i0 = 0 o 1)
-1 = l'effetto durerà fino a quando l'ingresso verrà disattivato
compressor protection deactivation compressor delay (only if i0 = 2)