Setting Of The Y Scale - JUKI LK-1941 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 222
(3) Setting of the scale
Setting of the X scale

Setting of the Y scale

(4) Setting of the max. sewing speed limitation
(5) Setting of the heat cutter temperature (For Z type only)
26
1) Press the
key to indicate the item "X Scale".
2) Press the
or
range of 20% to 200%.
1) Press the
key to indicate the item "Y Scale".
2) Press the
or
range of 20% to 200%.
Enlargement/reduction is a mode of
enlargement/reduction of stitch length.
W h e n e n l a r g e m e n t / r e d u c t i o n i s
performed, the number of stitches is
fixed and the stitch length varies.
1) Press the
key to indicate the item "Speed".
2) Press the
or
the display. (Setting of 400 sti/min)
1) Press the
key to indicate the item "Cutter
TEMP.".
2) Press the
or
on the display. (Setting of level 3)
Hot wire plate is a consumable part.
L e v e l " 3 " o f t h e h e a t c u t t e r
temperature is the standard set value.
The higher the level is raised, the more
the thread trimming performance is
improved. However, when the level is
raised more than necessary, damage
or deterioration of the service life of
the hot wire plate may occur. When
thread trimming failure occurs at the
standard setting value, perform the
proper action referring to "( -5.
Troubles and corrective measures
(sewing conditions)".
key to set the scale in the
key to set the scale in the
key to indicate "
key to indicate the item "3"
"on

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lk-1942

Tabla de contenido