104
Trouble shooting
Code C28
Allows you to view and delete the error codes stored
(maximum 10) by the machine memory.
The last 10 different error codes are saved in the error
memory so that occurred malfunctions can be called up
and consulted by the user through remote diagnosis.
The most recent error code is saved in memory location
1. Previous error codes are gradually shifted down the
memory list.
—
Go into code C28.
CONSULTING THE ERROR COUNTERS
—
Press and release the "+" or "-" key to scroll
through the list of errors.
Note: When the key is pressed the number of the
error in the list is shown, whilst when the
key is released the corresponding code
appears.
Press the STAR key to make the error number
—
appear again (on the left) and the total number of
times that error was repeated since the last time
the memory was cleared (on the right).
RESET OF ERROR COUNTERS
—
Press ENTER.
—
Make the selection.
0* = Do not clear the error memory
1 = Clear the error memory
—
Press ENTER.
*
= Factory confi guration