Enclosed Documents Technical Data - Hitecsa 117 Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Technical Data
Table "A": Technical Data
EQUI PF model
Fan coil application
Cooling capacity MIN/NOM/MAX (1)
Nominal cooling capacity (1) (*) EN 14511:2013
EER EN 14511:2013 (1) (*)
ESEER EN 14511:2013
Application radiant
Cooling capacity MIN/NOM/MAX (3)
Nominal cooling capacity (3) (*) EN 14511:2013
EER EN 14511:2013 (3)
Sound pressure (5)
Sound power (6)
Machine body sound power
Scroll compressor
Fans
Fan nominal air flow
Available static head
Maximum available static head
Heat exchanger water content
Water storage tank content
Heat exchanger nominal flow water side (1)
Residual head (P0/ASP0 installation) (1)
Residual head (PI0/ASPI0 installation) (1)
Residual head (P1/ASP1 mounting) (1)
Amount of R410A refrigerant
Amount of Oil PVE
Electrical data
Absorbed power in summer mode NOM (1) (●)
Absorbed power in summer mode NOM (3) (●)
Pump absorbed power (P0/PI0-ASP0/ASPI0)
Pump absorbed power (P1/ASP1)
Electrical power supply
Auxiliary power supply
Nominal current
Maximum current (■)
Pump absorbed current (P0/PI0-ASP0/ASPI0)
Pump absorbed current (P1/ASP1)
Dimensions
Width P0/PI0/P1
Width ASP0/ASPI0/ASP1
Height P0/PI0/P1
Height ASP0/ASPI0/ASP1
Depth P0/PI0/P1
Depth ASP0/ASPI0/ASP1
Water connections
(*) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential at
evaporator 5°C.
(3) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 18°C; temperature differential at
evaporator 5°C.
(5) Sound pressure level in dB(A) referring to a
5 m distance from the unit, in directionality
factor equal to Q=2.
(6) Sound power level in dB(A) on the basis of
measurements taken in accordance with UNI
EN-ISO 9614 and Eurovent 8/1 Standards.
IOM_EQUI PF-EQUHI PF_117a128_207983_200101_ES-EN-FR-DE-IT
kW
kW
kW
kW
dB(A)
dB(A)
dB(A)
n° x kW
m3/h
Pa
Pa
l
l
l/h
kPa
kPa
kPa
kW
kW
kW
kW
V-ph-Hz
V-ph-Hz
A
A
A
A
mm
mm
mm
mm
mm
mm
Ø
(■) Current drawn by the compressor and fans.
(●) Power absorbed by the compressor and
fans.
(*) The data according to EN14511 refer
staging P0/PI0/ASP0/ASPI0. Refer to the
section "Attachments Technical Note" to the
data of the establishment P1/ASP1.
96
117
124
8,5/16,2/17,1
12,3/24/25,6
16,40
24,30
3,13
2,98
4,47
4,53
11,1/20,4/21,4 14,8/28,1/29,9 16,0/32,3/33,6
20,60
28,40
4,16
4,1
53
53
77
77
68
68
Scroll regulated by inverter
1x0,814
1x0,814
7600
7600
80
80
800
800
1,5
1,9
110
110
2800
4100
89/87
89/83
89/87
89/83
148/145
113/108
3,05
4,05
1,6
5,4
8,4
5,1
7,2
0,3
0,3
0,6
0,6
400-3+N-50
230-1-50
10,91
14,92
19,2
27,4
1,37
1,37
2,72
2,72
1522
1522
1625
1625
1280
1280
1590
1590
835
835
845
845
1 ½"
1 ½"
ESEER (European Sesonal EER) European
average seasonal efficiency.
ESEER+ with AdaptiveFunction Plus logic.
128
13,1/27,2/28,3
27,50
3,05
4,58
32,60
4,01
56
80
71
1x1,02
8640
80
800
1,9
110
4700
76/69
76/69
124/117
4,6
9,3
8,3
0,3
0,6
16,77
27,4
1,37
1,58
1522
1625
1280
1590
835
845
1 ½"

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

124128

Tabla de contenido