3.2 Type key
Example
DCD
Pos.
1
Pos.
Code
1
DCD
2
318
3
400
4
3
5
23
6
7
DOL
8
-IGM
6
318
400
2
3
Explanation
Number of pumps
•
DC: One pump
•
DCD: Two pumps
Type number
•
318: Control cabinet without main switch
•
319: Control cabinet with main switch
Supply voltage and frequency
•
230: 230 V, 50/60 Hz
•
400: 400 V, 50/60 Hz
Number of phases
•
1: Single-phase
•
3: Three-phase
Maximum current per pump [A]
1: 1 - 1.5
2: 1.5 - 2.5
4: 2.5 - 4
5: 1-5
6: 4-6
10: 6-10
12: 5-12
16: 10-16
20: 5.5 - 20
23: 12-23
25: 20-25
Run/starting capacitor [μF] (only 12 A operating current)
•
[ ]: Without capacitor
•
30: Run capacitor
•
30/150: 30 μF run capacitor and 150 μF starting capacitor
Starting method
•
DOL: Direct-on-line starting
•
SD: Star-delta starting
•
SS: Soft starter
Setup
•
S: Standard
•
I: IO 113 (both pumps)
•
G: GSM module and battery backup
•
M: Mixer/flush valve
•
IG: IO 113, GSM module and battery backup
•
IM: IO 113 and mixer/flush valve
•
GM: GSM module, battery backup and mixer/flush valve
•
IGM: IO 113, GSM module, battery backup and mixer/flush valve
3
23
4
5
6
30: 10-30
32: 25-32
40: 32-40
50: 40-50
57: 40-57
58: 50-58
59: 15.5 - 59
65: 55-65
75: 65-75
85: 15.5 - 85
100: 70-100
DOL
-IGM
7
8